Back to Search Start Over

Simultaneous detection of dual microRNAs related to EV71 using ICP-MS based on metal nanoparticle labeling with hybridization chain reaction.

Authors :
Wang Y
Shao L
Zhao Z
Huang C
Jiao Y
Sun D
Liu R
Jiang D
Gao X
Source :
Analytica chimica acta [Anal Chim Acta] 2024 Mar 15; Vol. 1294, pp. 342272. Date of Electronic Publication: 2024 Jan 22.
Publication Year :
2024

Abstract

Background: Hand, foot, and mouth (HMFD) disease caused by enterovirus 71 (EV 71), is closely associated with severe clinical manifestations and can be deadly. Early detection of EV 71 can be achieved by detecting the increment in miR296 and miR16 in the serum. Using HCR to amplify signals and convert biological signals into metal nanoparticle signals detectable by ICP-MS is a detection method that can collect more accurate and reliable information, compared with traditional methods, in the detection of biological samples.<br />Results: We described a strategy for the simultaneous detection of miR296 and miR16 by ICP-MS based on metal nanoparticles (NPs) labeling with HCR. Briefly, single-stranded DNA (ssDNA) and magnetic beads (MBs), as well as NPs and signal probes for miRNA (Sp <subscript>-miR</subscript> ) were firstly conjugated via the streptavidin-biotin recognition system, constituting ssDNA-MBs and NPs-Sp <subscript>-miR</subscript> complex, respectively. The latter complex then hybridized with the former through HCR, generating the nanosensors for targets. Then, the targets were added and hybridized with ssDNA, and the HCR complex with NPs was released into the solution. Finally, the corresponding signals of the NPs were measured by ICP-MS. Results demonstrated that the developed method had good sensitivity and satisfactory selectivity and precision. Furthermore, when applied to biological samples with a complex matrix, the developed method also showed good recovery (88 % - 92 %) and reproducibility (RSD<10 %).<br />Significance: This method contributes to the early diagnosis of HFMD and opens up ideas for the further development of high-throughput biomarker detection. The strategy has practical potential for miR296 and miR16 detection in biological samples and provides a promising tool for multiple miRNA detection.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-4324
Volume :
1294
Database :
MEDLINE
Journal :
Analytica chimica acta
Publication Type :
Academic Journal
Accession number :
38336408
Full Text :
https://doi.org/10.1016/j.aca.2024.342272