Back to Search
Start Over
Multi-aspect analysis of ureteral access sheath usage in retrograde intrarenal surgery: A RIRSearch group study.
- Source :
-
Asian journal of urology [Asian J Urol] 2024 Jan; Vol. 11 (1), pp. 80-85. Date of Electronic Publication: 2021 Nov 20. - Publication Year :
- 2024
-
Abstract
- Objective: To evaluate the effect of ureteral access sheath (UAS) use and calibration change on stone-free rate and complications of retrograde intrarenal surgery (RIRS).<br />Methods: Data from 568 patients undergoing RIRS for kidney or upper ureteral stones were retrospectively included. Firstly, patients were compared after 1:1 propensity score matching, according to UAS usage during RIRS (UAS used [ <superscript>+</superscript> ] 87 and UAS non-used [ <superscript>-</superscript> ] 87 patients). Then all UAS <superscript>+</superscript>  patients ( n =481) were subdivided according to UAS calibration: 9.5-11.5 Fr, 10-12 Fr, 11-13 Fr, and 13-15 Fr. Primary outcomes of the study were the success and complications of RIRS.<br />Results: Stone-free rate of UAS <superscript>+</superscript>  patients (86.2%) was significantly higher than UAS <superscript>-</superscript> patients (70.1%) after propensity score matching ( p =0.01). Stone-free rate increased with higher caliber UAS (9.5-11.5 Fr: 66.7%; 10-12 Fr: 87.0%; 11-13 Fr: 90.6%; 13-15 Fr: 100%; p <0.001). Postoperative complications of UAS <superscript>+</superscript>  patients (11.5%) were significantly lower than UAS <superscript>-</superscript> patients (27.6%) ( p =0.01). Complications (8.7%) with 9.5-11.5 Fr UAS was lower than thicker UAS (17.2%) but was not statistically significant ( p =0.09). UAS usage was an independent factor predicting stone-free status or peri- and post-operative complications (odds ratio [OR] 3.654, 95% confidence interval [CI] 1.314-10.162; OR 4.443, 95% CI 1.350-14.552; OR 4.107, 95% CI 1.366-12.344, respectively).<br />Conclusion: Use of UAS in RIRS may increase stone-free rates, which also increase with higher caliber UAS. UAS usage may reduce complications; however, complications seemingly increase with higher UAS calibration.<br />Competing Interests: The authors declare no conflict of interest.<br /> (© 2024 Editorial Office of Asian Journal of Urology. Production and hosting by Elsevier B.V.)
Details
- Language :
- English
- ISSN :
- 2214-3882
- Volume :
- 11
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Asian journal of urology
- Publication Type :
- Academic Journal
- Accession number :
- 38312818
- Full Text :
- https://doi.org/10.1016/j.ajur.2021.11.004