Back to Search Start Over

Investigation of low-temperature partitioning with dispersive solid-phase extraction for quantification of pesticides in apples followed by electrospray-ionization mobility spectrometry: Comparison with conventional procedure.

Authors :
Liu W
Liu F
Che A
Chen Y
Cai J
Liu W
Jing G
Li W
Yu J
Source :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2024 Feb 15; Vol. 1234, pp. 124014. Date of Electronic Publication: 2024 Jan 26.
Publication Year :
2024

Abstract

Ion mobility spectrometry (IMS) has a promising application prospect in food surveillance. However, due to the complexity of food matrix and trace levels of pesticide residues, the effective and rapid detection of pesticides by IMS has been a challenge, especially when using electrospray ionization (ESI) as an ion source. In this study, low-temperature partitioning with dispersive solid-phase extraction (LTP-dSPE) was explored and compared with conventional procedures. Both methods were validated for the quantification of eight pesticides in apples, obtaining a limit of detection (LOD) of 0.02-0.12 mg/kg for LTP-dSPE and 0.02-0.09 mg/kg for conventional solid-phase extraction (SPE), lower than those usually stipulated by government legislation in food matrices. For LTP-dSPE, the matrx effect (ME) ranged from -16.3 to -68.6 %, lower than that for the SPE method, ranging from -70.0 to -92.9 %. The results showed satisfactory efficiency and precision, with recovery values ranging from 67.9 to 115.4 % for LTP-dSPE and from 62.0 to 114.8 % for conventional SPE, with relative standard deviations below 13.0 %. Notably, the proposed LTP-dSPE/ESI-IMS has been shown to be more cost-effective, easier to use, more environment-friendly, more accessible, and, most importantly, less matrix effect than the conventional method, thereby being suitably applicable to a wide range of food safety applications.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-376X
Volume :
1234
Database :
MEDLINE
Journal :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Publication Type :
Academic Journal
Accession number :
38306956
Full Text :
https://doi.org/10.1016/j.jchromb.2024.124014