Back to Search Start Over

Feasibility of Saphenous Nerve Somatosensory-Evoked Potential Intraoperative Monitoring During Lumbar Spine Surgery: Early Results.

Authors :
Rucker S
Singh N
Mai E
Asada T
Shahi P
Mercado K
Leung D
Iyer S
Emerson R
Qureshi SA
Source :
Spine [Spine (Phila Pa 1976)] 2024 Jul 01; Vol. 49 (13), pp. 923-932. Date of Electronic Publication: 2024 Jan 26.
Publication Year :
2024

Abstract

Study Design: Retrospective review.<br />Objective: Assess the feasibility of saphenous nerve somatosensory evoked potentials (SN-SSEP) monitoring in lumbar spine surgeries.<br />Background Context: SN-SSEPs have been proposed for detecting lumbar plexus and femoral nerve injury during lateral lumbar surgery where tibial nerve (TN) SSEPs alone are insufficient. SN-SSEPs may also be useful in other types of lumbar surgery, as stimulation of SN below the knee derives solely from the L4 root and provides a means of L4 monitoring, whereas TN-SSEPs often do not detect single nerve root injury. The feasibility of routine SN-SSEP monitoring has not been established.<br />Methods: A total of 563 consecutive cases using both TN-SSEP and SN-SSEP monitoring were included. Anesthesia was at the discretion of the anesthesiologist, using an inhalant in 97.7% of procedures. SN stimulation was performed using 13 mm needle electrodes placed below the knee using 200-400 μsec pulses at 15 to 100 mA. Adjustments to stimulation parameters were made by the neurophysiology technician while obtaining baselines. Data were graded retrospectively for monitorability and cortical response amplitudes were measured by two independent reviewers.<br />Results: Ninety-eight percent of TN-SSEPs and 92.5% of SN-SSEPs were monitorable at baseline, with a mean response amplitude of 1.35 μV for TN-SSEPs and 0.71 μV for SN-SSEPs. A significant difference between the stimulation parameters used to obtain reproducible TN and SN-SSEPs at baseline was observed, with SN-SSEPs requiring greater stimulation intensities. Body mass index is not associated with baseline monitorability. Out of 20 signal changes observed, 11 involved SN, while TN-SSEPs were unaffected.<br />Conclusion: With adjustments to stimulation parameters, SN-SSEP monitoring is feasible within a large clinical cohort without modifications to the anesthetic plan. Incorporating SN into standard intraoperative neurophysiological monitoring protocols for lumbar spine procedures may expand the role of SSEP monitoring to include detecting injury to the lumbar plexus.<br />Level of Evidence: 3.<br />Competing Interests: S.Q.—AMOpportunities: Other financial or material support; Annals of Translational Medicine: Editorial or governing board; Association of Bone and Joint Surgeons: Board or committee member; Cervical Spine Research Society: Board or committee member; Contemporary Spine Surgery: Editorial or governing board; Globus Medical: IP royalties; Paid consultant; Paid presenter or speaker; Hospital Special Surgery Journal: Editorial or governing board; HS2, LLC: Stock or stock Options; International Society for the Advancement of Spine Surgery (ISASS) - Program Committee member: Board or committee member; Lifelink.com: Other financial or material support; Lumbar Spine Research Society: Board or committee member; Minimally Invasive Spine Study Group: Board or committee member; North American Spine Society: Board or committee member; Simplify Medical, Inc.: Other financial or material support; Society of Minimally Invasive Spine Surgery (SMISS) - Program Committee member: Board or committee member; Spinal Simplicity: Other financial or material support; SpineGuard, Inc.: Paid consultant; Stryker: IP royalties; Paid consultant; Surgalign: Paid consultant; Tissue Differentiation Intelligence: Stock or stock Options; Viseon, Inc.: Paid consultant; Research support; Clinical Spine Surgery: Editorial or governing board. S.I.—Globus Medical: Paid presenter or speaker; Stryker: Paid presenter or speaker; Vertebral Columns/International Society for the Advancement of Spine Surgery (ISASS): Editorial or governing board; HS2, LLC: Ownership/Equity/Investment; Innovasis: Research Support (either personally or through institution). The remaining authors report no conflicts of interest.<br /> (Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1528-1159
Volume :
49
Issue :
13
Database :
MEDLINE
Journal :
Spine
Publication Type :
Academic Journal
Accession number :
38273786
Full Text :
https://doi.org/10.1097/BRS.0000000000004938