Back to Search Start Over

Twelve-month follow-up results from the SIRONA 2 clinical trial.

Authors :
Sharif F
Rosenkranz S
Bartunek J
Kempf T
Aßmus B
Mahon NG
Hiivala NJ
Mullens W
Source :
ESC heart failure [ESC Heart Fail] 2024 Apr; Vol. 11 (2), pp. 1133-1143. Date of Electronic Publication: 2024 Jan 25.
Publication Year :
2024

Abstract

Aims: In the SIRONA 2 trial, the safety and efficacy of pulmonary artery (PA) pressure (PAP)-guided heart failure (HF) management using a novel PAP sensor were assessed at 30 and 90 days, respectively, and both endpoints were met. The current study examines the prespecified secondary endpoints of safety and accuracy of the PA sensor along with HF hospitalizations and mortality, HF symptoms, functional capacity, quality of life, and patient compliance through 12 months.<br />Methods and Results: SIRONA 2 is a prospective, multi-centre, open-label, single-arm trial evaluating the Cordella™ PA Sensor System in 70 patients with New York Heart Association (NYHA) functional class III HF with a prior HF hospitalization and/or increase of N-terminal pro-brain natriuretic peptide within 12 months of enrolment. Sensor accuracy was assessed and compared with measurements obtained by standard right heart catheterization (RHC). Safety was defined as freedom from prespecified adverse events associated with use of the Cordella PA Sensor System and was assessed in all patients who entered the cath lab for PA sensor implant. HF hospitalizations and mortality, HF symptoms, functional capacity, quality of life, and patient compliance were also assessed. At 12 months, there was good agreement between the Cordella PA Sensor System and RHC, with the average difference for mean PAP being 2.9 ± 7.3 mmHg. The device safety profile was excellent with 98.4% freedom from device/system-related complications. There were no pressure sensor failures. HF hospitalizations and mortality were low with a rate of 0.33 event per patient year. Symptoms as assessed by NYHA (P < 0.0001) and functional capacity as measured by 6 min walk test (P = 0.02) were significantly improved. Patients' adherence to daily transmissions of PAP and vital signs measurements was 95%.<br />Conclusions: Long-term follow-up of the SIRONA 2 trial supports the safety and accuracy of the Cordella PA Sensor System in enabling comprehensive HF management in NYHA class III HF patients.<br /> (© 2024 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.)

Details

Language :
English
ISSN :
2055-5822
Volume :
11
Issue :
2
Database :
MEDLINE
Journal :
ESC heart failure
Publication Type :
Academic Journal
Accession number :
38271076
Full Text :
https://doi.org/10.1002/ehf2.14657