Back to Search Start Over

Role of Additional MRI-Based Morphologic Measurements on the Performance of VI-RADS for Muscle-Invasive Bladder Cancer.

Authors :
Gong Y
Cheng Y
Zhang J
Bao ML
Zhu FP
Sun XY
Zhang YD
Source :
Journal of magnetic resonance imaging : JMRI [J Magn Reson Imaging] 2024 Sep; Vol. 60 (3), pp. 1113-1123. Date of Electronic Publication: 2024 Jan 23.
Publication Year :
2024

Abstract

Background: Vesical Imaging-Reporting and Data System (VI-RADS) is a pathway for the standardized imaging and reporting of bladder cancer staging using multiparametric (mp) MRI.<br />Purpose: To investigate additional role of morphological (MOR) measurements to VI-RADS for the detection of muscle-invasive bladder cancer (MIBC) with mpMRI.<br />Study Type: Retrospective.<br />Population: A total of 198 patients (72 MIBC and 126 NMIBC) underwent bladder mpMRI was included.<br />Field Strength/sequence: 3.0 T/T2-weighted imaging with fast-spin-echo sequence, spin-echo-planar diffusion-weighted imaging and dynamic contrast-enhanced imaging with fast 3D gradient-echo sequence.<br />Assessment: VI-RADS score and MOR measurement including tumor location, number, stalk, cauliflower-like surface, type of tumor growth, tumor-muscle contact margin (TCM), tumor-longitudinal length (TLL), and tumor cellularity index (TCI) were analyzed by three uroradiologists (3-year, 8-year, and 15-year experience of bladder MRI, respectively) who were blinded to histopathology.<br />Statistical Tests: Significant MOR measurements associated with MIBC were tested by univariable and multivariable logistic regression (LR) analysis with odds ratio (OR). Area under receiver operating characteristic curve (AUC) with DeLong's test and decision curve analysis (DCA) were used to compared the performance of unadjusted vs. adjusted VI-RADS. A P-value <0.05 was considered statistically significant.<br />Results: TCM (OR 9.98; 95% confidence interval [CI] 4.77-20.8), TCI (OR 5.72; 95% CI 2.37-13.8), and TLL (OR 3.35; 95% CI 1.40-8.03) were independently associated with MIBC at multivariable LR analysis. VI-RADS adjusted by three MORs achieved significantly higher AUC (reader 1 0.908 vs. 0.798; reader 2 0.906 vs. 0.855; reader 3 0.907 vs. 0.831) and better clinical benefits than unadjusted VI-RADS at DCA. Specially in VI-RADS-defined equivocal lesions, MOR-based adjustment resulted in 55.5% (25/45), 70.4% (38/54), and 46.4% (26/56) improvement in accuracy for discriminating MIBC in three readers, respectively.<br />Data Conclusion: MOR measurements improved the performance of VI-RADS in detecting MIBC with mpMRI, especially for equivocal lesions.<br />Level of Evidence: 3 TECHNICAL EFFICACY: Stage 2.<br /> (© 2024 International Society for Magnetic Resonance in Medicine.)

Details

Language :
English
ISSN :
1522-2586
Volume :
60
Issue :
3
Database :
MEDLINE
Journal :
Journal of magnetic resonance imaging : JMRI
Publication Type :
Academic Journal
Accession number :
38258496
Full Text :
https://doi.org/10.1002/jmri.29184