Continuous glucose monitoring in pregnancies with type 1 diabetes: small increases in time-in-range improve maternal and perinatal outcomes.
- Source :
-
American journal of obstetrics and gynecology [Am J Obstet Gynecol] 2024 Oct; Vol. 231 (4), pp. 467.e1-467.e8. Date of Electronic Publication: 2024 Jan 17. - Publication Year :
- 2024
-
Abstract
- Background: Continuous glucose monitors provide detailed information regarding glycemic control in pregnant patients with type 1 diabetes. Little data have been published examining the association between continuous glucose monitor parameters and perinatal outcomes among gravidas with type 1 diabetes using continuous glucose monitors.<br />Objective: This study aimed to examine the association between perinatal outcomes and time-in-range as assessed by continuous glucose monitors used in pregnant individuals with type 1 diabetes. We hypothesized that higher time-in-range would be associated with lower risk of adverse perinatal outcomes.<br />Study Design: This multicenter retrospective cohort study included all gravidas with type 1 diabetes using continuous glucose monitors who delivered from 2020 to 2022 at 5 University of California sites. Only those with continuous glucose monitor target range set to 70 to 140 mg/dL (±10 mg/dL) were included. Time-in-range (%) was recorded at 12, 16, 20, 24, 28, and 32 weeks. The primary maternal and neonatal outcomes were preeclampsia and large for gestational age, defined as birthweight ≥95th percentile. Kruskal-Wallis tests were used to compare median time-in-range between those with and without the primary outcomes. Log-binomial regression was used to obtain risk ratios, with adjustment for microvascular disease and years with type 1 diabetes.<br />Results: A total of 91 patients were included. Most used an insulin pump (81%) and did not have diabetic microvascular disease (72%). Median time since diagnosis of type 1 diabetes was 16 years, and median periconception hemoglobin A1c was 6.7%. Compared with those with preeclampsia, normotensive gravidas had significantly higher time-in-range at nearly every time point. A similar pattern was observed for those with normal-birthweight infants compared with large-for-gestational-age infants. On adjusted analyses, every 5-unit increase in time-in-range at 12 weeks was associated with 45% and 46% reductions in the risks of preeclampsia and large for gestational age, respectively (preeclampsia: adjusted risk ratio, 0.55; 95% confidence interval, 0.30-0.99; large for gestational age: adjusted risk ratio, 0.54; 95% confidence interval, 0.29-0.99).<br />Conclusion: Higher time-in-range is associated with lower risk of preeclampsia and large for gestational age. This association is observed early in gestation, when each 5-unit increase in time-in-range is associated with ∼50% reduction in the risk of these complications. These findings can be used to counsel patients regarding the risk of pregnancy complications at specific time-in-range values, and to encourage patients that even small improvements in time-in-range can have significant impact on pregnancy outcomes. Larger studies are needed to further explore these findings and to identify optimal time-in-range to reduce perinatal complication rates.<br /> (Copyright © 2024 Elsevier Inc. All rights reserved.)
- Subjects :
- Humans
Pregnancy
Female
Adult
Retrospective Studies
Infant, Newborn
Blood Glucose Self-Monitoring
Fetal Macrosomia epidemiology
Pregnancy Outcome
Time Factors
Cohort Studies
Glycemic Control methods
Continuous Glucose Monitoring
Diabetes Mellitus, Type 1 blood
Diabetes Mellitus, Type 1 drug therapy
Pregnancy in Diabetics blood
Pre-Eclampsia blood
Blood Glucose analysis
Blood Glucose metabolism
Subjects
Details
- Language :
- English
- ISSN :
- 1097-6868
- Volume :
- 231
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- American journal of obstetrics and gynecology
- Publication Type :
- Academic Journal
- Accession number :
- 38242337
- Full Text :
- https://doi.org/10.1016/j.ajog.2024.01.010