Back to Search Start Over

Localization of Low- and High-Frequency Sounds in Cochlear Implant Recipients Using a Contralateral Hearing Aid.

Authors :
Zelger P
Zorowka P
Schmutzhard J
Galvan O
Rossi S
Stephan K
Seebacher J
Source :
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology [Otol Neurotol] 2024 Mar 01; Vol. 45 (3), pp. e228-e233. Date of Electronic Publication: 2024 Jan 10.
Publication Year :
2024

Abstract

Background and Objectives: The ability to localize sounds is partly recovered in patients using a cochlear implant (CI) in one ear and a hearing aid (HA) on the contralateral side. Binaural processing seems effective at least to some extent, despite the difference between electric and acoustic stimulation in each ear. To obtain further insights into the mechanisms of binaural hearing in these listeners, localization of low- and high-frequency sounds was tested.<br />Study Design: The study used a within-subject design, where participants were tasked with localizing sound sources in the horizontal plane. The experiment was conducted in an anechoic chamber, where an array of seven loudspeakers was mounted along the 24 azimuthal angle span from -90° to +90°. Stimuli were applied with different frequencies: broadband noise and high- and low-frequency noise.<br />Subjects: Ten CI recipients participated in the study. All had an asymmetric hearing loss with a CI in the poorer ear and an HA on the contralateral side.<br />Main Outcome Measures: Accuracy of sound localization in terms of angular error and percentage of correct localization scores.<br />Results: The median angular error was 40° in bimodal conditions for both broadband noise and high-frequency noise stimuli. The angular error increased to 47° for low-frequency noise stimuli. In the unilaterally aided condition with an HA, only a median angular error of 78° was observed.<br />Conclusions: Irrespective of the frequency composition of the stimuli, this group of bimodal listeners showed some ability to localize sounds. Angular errors were larger than those reported in the literature for bilateral CI users or single-sided deaf listeners with a CI. In the unilateral listening condition with HA, only localization of sounds was not possible for most subjects.<br />Competing Interests: Conflict of interest: The authors declare no conflicts of interest.<br /> (Copyright © 2024, Otology & Neurotology, Inc.)

Details

Language :
English
ISSN :
1537-4505
Volume :
45
Issue :
3
Database :
MEDLINE
Journal :
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
Publication Type :
Academic Journal
Accession number :
38238908
Full Text :
https://doi.org/10.1097/MAO.0000000000004090