Back to Search Start Over

Mid-term real world outcomes of the Hydrus ® Microstent in open angle glaucoma.

Authors :
Kiramira D
Voßmerbäumer U
Pfeiffer N
Linnerth-Braun LKM
Lorenz K
Prokosch V
Source :
Eye (London, England) [Eye (Lond)] 2024 Jun; Vol. 38 (8), pp. 1454-1461. Date of Electronic Publication: 2024 Jan 05.
Publication Year :
2024

Abstract

Purpose: To evaluate the mid-term clinical results and the safety aspects of the Hydrus <superscript>®</superscript> Microstent (Ivantis, Inc, Irvine, CA) in a real-life setting.<br />Design: Retrospective case series.<br />Methods: Hydrus <superscript>®</superscript> Microstent was implanted in phakic eyes (88 eyes, 87.1%) and in pseudophakic eyes (13 eyes, 12.9%), respectively. Mean follow-up time was 16 ± 9 months with 27 eyes having a follow-up time of more than 24 months.<br />Main Outcome Measures: The primary endpoint was reduction in IOP compared to baseline. Target IOP levels were set at ≤20 mmHg, ≤18 mmHg and ≤15 mmHg. Kaplan-Meier survival was defined as a reduction in IOP of ≥20% compared to baseline. Secondary endpoints were reduction in number of glaucoma medications and safety assessments addressing visual acuity, adverse events, re-surgery rate and identification of factors that made the implantation more difficult.<br />Result: 101 eyes underwent Hydrus <superscript>®</superscript> implantation. The mean preoperative IOP was 21.60 mmHg (SD 6.6) on 2.18 (SD 1.3) medications. After a mean follow up time of 16 months, the mean IOP was reduced to 14.61 ± 3.7 mmHg on 1.12 (SD 1.1) medication classes (p < 0.001). Mean decrease in IOP was 26.7%. Analysis of the target IOP levels showed that in 29%, 34% and 35% of cases an IOP of ≤15 mmHg, ≤18 mmHg and ≤20 mmHg respectively could be achieved. BCVA improved from 0.56 ± 0.3 at baseline to 0.85 ± 0.3 more than 24 months after surgery (p < 0.001). The rate of re-operation was low at <3%. Adverse events occurred in 4 eyes (<4%).<br />Conclusion: This study underlines the effectiveness and the safety of the Hydrus <superscript>®</superscript> Microstent in an elective setting, but it also demonstrates certain limits and risk factors of this procedure.<br /> (© 2024. The Author(s), under exclusive licence to The Royal College of Ophthalmologists.)

Details

Language :
English
ISSN :
1476-5454
Volume :
38
Issue :
8
Database :
MEDLINE
Journal :
Eye (London, England)
Publication Type :
Academic Journal
Accession number :
38182656
Full Text :
https://doi.org/10.1038/s41433-023-02920-2