Back to Search
Start Over
Short-term safety and effectiveness of the mCLIP partial prosthesis.
- Source :
-
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery [Eur Arch Otorhinolaryngol] 2024 May; Vol. 281 (5), pp. 2353-2363. Date of Electronic Publication: 2023 Dec 22. - Publication Year :
- 2024
-
Abstract
- Purpose: This multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP Partial Prosthesis.<br />Methods: Patients underwent tympanoplasty with implantation of a mCLIP Partial Prosthesis. Follow-up examination included ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA <subscript>4</subscript> ). The post-operative PTA <subscript>4</subscript> air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined. Thus, the follow-up times of each study center were different, which resulted in different follow-up times for the audiological analysis and for adverse events (AE).<br />Results: 72 (66 adults, 6 children) patients were implanted with the mCLIP Partial Prosthesis. 68 (62 adults, 6 children) patients underwent audiological examination; all 72 patients were examined for adverse events. All patients (N = 68): 72.1% of the patients showed a PTA <subscript>4</subscript> ABG of ≤ 20 dB. Individual post-operative bone conduction (BC) PTA <subscript>4</subscript> thresholds were stable in 67 patients. The mean post-operative follow-up time was 78 ± 46 days. Children (N = 6): 5 out of 6 children showed a PTA <subscript>4</subscript> ABG of ≤ 20 dB. None of the children reported a BC PTA <subscript>4</subscript> deterioration of > 10 dB HL after the implantation. The mean post-operative follow-up time was 101 ± 45 days. Adverse events (all patients, N = 72): 15 (14 adults, 1 child) patients had AEs (27 AEs and 2 Follow-Ups). The mean post-operative follow-up time was 375 days.<br />Conclusion: Clinical data show satisfactory audiological parameters after implantation of the mCLIP Partial Prosthesis. The prosthesis is safe and effective for implantation in children and adults.<br />Trial Registration Number: NCT05565339, 09 September 2022, retrospectively registered.<br /> (© 2023. The Author(s).)
Details
- Language :
- English
- ISSN :
- 1434-4726
- Volume :
- 281
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 38133806
- Full Text :
- https://doi.org/10.1007/s00405-023-08359-1