Back to Search Start Over

Impact of coagulation on SARS-CoV-2 and PMMoV viral signal in wastewater solids.

Authors :
Hegazy N
Tian X
D'Aoust PM
Pisharody L
Towhid ST
Mercier É
Zhang Z
Wan S
Thakali O
Kabir MP
Fang W
Nguyen TB
Ramsay NT
MacKenzie AE
Graber TE
Guilherme S
Delatolla R
Source :
Environmental science and pollution research international [Environ Sci Pollut Res Int] 2024 Jan; Vol. 31 (4), pp. 5242-5253. Date of Electronic Publication: 2023 Dec 19.
Publication Year :
2024

Abstract

Wastewater surveillance (WWS) of SARS-CoV-2 has become a crucial tool for monitoring COVID-19 cases and outbreaks. Previous studies have indicated that SARS-CoV-2 RNA measurement from testing solid-rich primary sludge yields better sensitivity compared to testing wastewater influent. Furthermore, measurement of pepper mild mottle virus (PMMoV) signal in wastewater allows for precise normalization of SARS-CoV-2 viral signal based on solid content, enhancing disease prevalence tracking. However, despite the widespread adoption of WWS, a knowledge gap remains regarding the impact of ferric sulfate coagulation, commonly used in enhanced primary clarification, the initial stage of wastewater treatment where solids are sedimented and removed, on SARS-CoV-2 and PMMoV quantification in wastewater-based epidemiology. This study examines the effects of ferric sulfate addition, along with the associated pH reduction, on the measurement of SARS-CoV-2 and PMMoV viral measurements in wastewater primary clarified sludge through jar testing. Results show that the addition of Fe <superscript>3+</superscript> concentrations in the conventional 0 to 60 mg/L range caused no effect on SARS-CoV-2 N1 and N2 gene region measurements in wastewater solids. However, elevated Fe <superscript>3+</superscript> concentrations were shown to be associated with a statistically significant increase in PMMoV viral measurements in wastewater solids, which consequently resulted in the underestimation of PMMoV-normalized SARS-CoV-2 viral signal measurements (N1 and N2 copies/copies of PMMoV). The observed pH reduction from coagulant addition did not contribute to the increased PMMoV measurements, suggesting that this phenomenon arises from the partitioning of PMMoV viral particles into wastewater solids.<br /> (© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)

Details

Language :
English
ISSN :
1614-7499
Volume :
31
Issue :
4
Database :
MEDLINE
Journal :
Environmental science and pollution research international
Publication Type :
Academic Journal
Accession number :
38112868
Full Text :
https://doi.org/10.1007/s11356-023-31444-1