Back to Search Start Over

Diagnostic accuracy of smartphone corneal photography for detection of corneal opacities in a resource-limited setting: a community-based study.

Authors :
Cao B
Giri P
Byanju R
Pradhan S
Bhandari G
Bhandari S
Kandel RP
Poudyal B
Gonzales JA
Srinivasan M
Upadhyay M
Whitcher JP
O'Brien KS
Lietman TM
Keenan JD
Source :
Cornea open [Cornea Open] 2023 Sep; Vol. 2 (3). Date of Electronic Publication: 2023 Sep 19.
Publication Year :
2023

Abstract

Purpose: To evaluate the diagnostic accuracy of smartphone corneal photography in detecting corneal opacities in a community-based setting.<br />Methods: A case-control, diagnostic accuracy study was nested in a cluster-randomized trial of a corneal ulcer prevention intervention in Nepal. Smartphone corneal photography was performed annually on community members self-reporting a potential risk factor for a corneal infection. Corneal photographs were graded for the presence or absence of an opacity. All cases with an opacity on smartphone photography and an equal number of controls were invited for a comprehensive eye examination with a slit lamp biomicroscope at an eye hospital. A mobile team visited participants unable to come to the hospital, conducting a limited examination with a penlight.<br />Results: Of 1332 study participants (666 cases and 666 controls), 1097 had a penlight examination (535 cases and 562 controls) and 191 had a slit lamp examination (120 cases and 71 controls). When penlight examination was considered the reference standard, smartphone diagnosis of a corneal opacity had a positive predictive value (PPV) of 47% (95% confidence interval 43-52%) and negative predictive value (NPV) of 95% (93-97%). When slit lamp examination was considered the reference standard, the overall PPV and NPV were 71% (62-78%) and 80% (70-88%), respectively. The NPV was greater for detection of opacities > 1mm, estimated at 95% (90-98%).<br />Conclusions: Corneal photography performed in a resource-limited community-based setting using a smartphone coupled to an external attachment had acceptable diagnostic accuracy for detection of corneal opacities large enough to be clinically meaningful.<br />Competing Interests: Conflicts of Interest The authors declare no conflicts of interest.

Details

Language :
English
ISSN :
2833-6992
Volume :
2
Issue :
3
Database :
MEDLINE
Journal :
Cornea open
Publication Type :
Academic Journal
Accession number :
38076595
Full Text :
https://doi.org/10.1097/coa.0000000000000018