Back to Search
Start Over
Reproducibility of the Mayo and Schatzker classification systems in proximal ulna fractures.
- Source :
-
Orthopaedics & traumatology, surgery & research : OTSR [Orthop Traumatol Surg Res] 2024 May; Vol. 110 (3), pp. 103790. Date of Electronic Publication: 2023 Dec 08. - Publication Year :
- 2024
-
Abstract
- Introduction: A fracture classification system should provide a reliable and reproducible means of communication between different parties. It should be logical and understandable, with few categories to memorize. The aim of this study was to determine the intra- and interobserver reliability of the Schatzker and Mayo classification systems for the assessment of proximal ulna fractures.<br />Materials and Methods: Intra- and interobserver reliability studies were conducted on 39 X-rays of injured elbows drawn randomly from 74 cases previously used in a series on predictors of ulnohumeral osteoarthritis in proximal ulna fractures. Ten observers independently reviewed these X-rays on 2 separate occasions 3 months apart. The fracture type was assessed according to the Schatzker and Mayo classification systems during each reading session. Cohen's and Fleiss' kappa were used to measure the intra- and interobserver reliability.<br />Results: The Schatzker classification had a fair interobserver reliability for the first (Schatzker R <subscript>1</subscript> , Fleiss' κ: 0.394) and second (Schatzker R <subscript>2</subscript> , Fleiss' κ: 0.351) readings. The mean intraobserver reliability value between the 10 reviewers for the Schatzker classification was rated as substantial (0.61). The Mayo classification had a fair interobserver reliability for the first (Mayo R <subscript>1</subscript> , Fleiss' κ: 0.278) and second (Mayo R <subscript>2</subscript> , Fleiss' κ: 0.292) readings. The mean intraobserver reliability value between the 10 reviewers for the Mayo classification was rated as fair (0.52).<br />Discussion: The classification systems for proximal ulna fractures showed poor reproducibility between the different observers since they had low interobserver agreement values. Nevertheless, their use remained reliable since the measured intraobserver agreement value was deemed substantial.<br />Level of Evidence: IV; retrospective.<br /> (Copyright © 2023 Elsevier Masson SAS. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1877-0568
- Volume :
- 110
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Orthopaedics & traumatology, surgery & research : OTSR
- Publication Type :
- Academic Journal
- Accession number :
- 38070730
- Full Text :
- https://doi.org/10.1016/j.otsr.2023.103790