Back to Search Start Over

Translation, cultural adaptation, and validation of the Chinese standardized outcomes in nephrology-hemodialysis fatigue (C-SONG-HD fatigue) scale: a study of Chinese patients undergoing hemodialysis.

Authors :
Huang LT
Zheng XY
Zhang ZH
Zheng HY
Wei X
Yang JY
Zhang LH
Lu XQ
Yang YQ
Lin JX
Zhang CM
Luo LP
Jiang DH
Huang SH
Huang XB
Zhan YM
Xu WZ
Han W
Hong FY
Source :
Quality of life research : an international journal of quality of life aspects of treatment, care and rehabilitation [Qual Life Res] 2024 Mar; Vol. 33 (3), pp. 745-752. Date of Electronic Publication: 2023 Dec 08.
Publication Year :
2024

Abstract

Objective: This study aimed to translate and culturally adapt the standardized outcomes in nephrology-hemodialysis fatigue (SONG-HD fatigue) scale and to assess the psychometric properties of the Chinese version of the SONG-HD fatigue (C-SONG-HD fatigue) scale.<br />Methods: Forward and back translations were used to translate the SONG-HD fatigue scale into Chinese. We used the C-SONG-HD fatigue scale to survey Chinese patients undergoing hemodialysis (HD) in China. We examined the distribution of responses and floor and ceiling effects. Cronbach's alpha and McDonald's omega coefficient, intraclass coefficients, and Spearman correlations were used to assess internal consistency reliability, test-retest reliability, and convergent validity, respectively. Responsiveness was also evaluated.<br />Results: In total, 489 participants across southeast China, northwest China, and central China completed the study. The C-SONG-HD fatigue scale had good internal consistency (Cronbach's alpha coefficient 0.861, omega coefficient 0.916), test-retest reliability (intraclass correlation coefficient 0.695), and convergent validity (Spearman correlation 0.691). The analysis of all first-time HD patients did not show notable responsiveness, and only patients with temporary vascular access had good responsiveness with an effect size (ES) of 0.54, a standardized response mean (SRM) of 0.85, and a standard error of measurement (SEM) of 0.77.<br />Conclusion: The Chinese version of the SONG-HD fatigue scale showed satisfactory reliability and validity in patients undergoing hemodialysis (HD) in China. It could be used as a tool to measure the fatigue of Chinese HD patients.<br /> (© 2023. The Author(s), under exclusive licence to Springer Nature Switzerland AG.)

Details

Language :
English
ISSN :
1573-2649
Volume :
33
Issue :
3
Database :
MEDLINE
Journal :
Quality of life research : an international journal of quality of life aspects of treatment, care and rehabilitation
Publication Type :
Academic Journal
Accession number :
38064016
Full Text :
https://doi.org/10.1007/s11136-023-03561-4