Back to Search Start Over

Active contact proximity to the cerebellothalamic tract predicts initial therapeutic current requirement with DBS for ET: an application of 7T MRI.

Authors :
Ikramuddin SS
Brinda AK
Butler RD
Hill ME
Dharnipragada R
Aman JE
Schrock LE
Cooper SE
Palnitkar T
Patriat R
Harel N
Vitek JL
Johnson MD
Source :
Frontiers in neurology [Front Neurol] 2023 Nov 09; Vol. 14, pp. 1258895. Date of Electronic Publication: 2023 Nov 09 (Print Publication: 2023).
Publication Year :
2023

Abstract

Objective: To characterize how the proximity of deep brain stimulation (DBS) active contact locations relative to the cerebellothalamic tract (CTT) affect clinical outcomes in patients with essential tremor (ET).<br />Background: DBS is an effective treatment for refractory ET. However, the role of the CTT in mediating the effect of DBS for ET is not well characterized. 7-Tesla (T) MRI-derived tractography provides a means to measure the distance between the active contact and the CTT more precisely.<br />Methods: A retrospective review was conducted of 12 brain hemispheres in 7 patients at a single center who underwent 7T MRI prior to ventral intermediate nucleus (VIM) DBS lead placement for ET following failed medical management. 7T-derived diffusion tractography imaging was used to identify the CTT and was merged with the post-operative CT to calculate the Euclidean distance from the active contact to the CTT. We collected optimized stimulation parameters at initial programing, 1- and 2-year follow up, as well as a baseline and postoperative Fahn-Tolosa-Marin (FTM) scores.<br />Results: The therapeutic DBS current mean (SD) across implants was 1.8 mA (1.8) at initial programming, 2.5 mA (0.6) at 1 year, and 2.9 mA (1.1) at 2-year follow up. Proximity of the clinically-optimized active contact to the CTT was 3.1 mm (1.2), which correlated with lower current requirements at the time of initial programming (R <superscript>2</superscript>  = 0.458, p  = 0.009), but not at the 1- and 2-year follow up visits. Subjects achieved mean (SD) improvement in tremor control of 77.9% (14.5) at mean follow-up time of 22.2 (18.9) months. Active contact distance to the CTT did not predict post-operative tremor control at the time of the longer term clinical follow up (R <superscript>2</superscript>  = -0.073, p  = 0.58).<br />Conclusion: Active DBS contact proximity to the CTT was associated with lower therapeutic current requirement following DBS surgery for ET, but therapeutic current was increased over time. Distance to CTT did not predict the need for increased current over time, or longer term post-operative tremor control in this cohort. Further study is needed to characterize the role of the CTT in long-term DBS outcomes.<br />Competing Interests: JV was a consultant for Medtronic, Boston Scientific, Abbott, and Cala Health, and serves on the External Advisory Board for Abbott and the Scientific Advisory Board for Surgical Information Sciences. NH was a co-founder and a consultant for Surgical Information Sciences. RP and TP were consultant for Surgical Information Services. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2023 Ikramuddin, Brinda, Butler, Hill, Dharnipragada, Aman, Schrock, Cooper, Palnitkar, Patriat, Harel, Vitek and Johnson.)

Details

Language :
English
ISSN :
1664-2295
Volume :
14
Database :
MEDLINE
Journal :
Frontiers in neurology
Publication Type :
Academic Journal
Accession number :
38020603
Full Text :
https://doi.org/10.3389/fneur.2023.1258895