Back to Search Start Over

Hyperkalemia Detection in Emergency Departments Using Initial ECGs: A Smartphone AI ECG Analyzer vs. Board-Certified Physicians.

Authors :
Kim D
Jeong J
Kim J
Cho Y
Park I
Lee SM
Oh YT
Baek S
Kang D
Lee E
Jeong B
Source :
Journal of Korean medical science [J Korean Med Sci] 2023 Nov 20; Vol. 38 (45), pp. e322. Date of Electronic Publication: 2023 Nov 20.
Publication Year :
2023

Abstract

Background: Hyperkalemia is a potentially fatal condition that mandates rapid identification in emergency departments (EDs). Although a 12-lead electrocardiogram (ECG) can indicate hyperkalemia, subtle changes in the ECG often pose detection challenges. An artificial intelligence application that accurately assesses hyperkalemia risk from ECGs could revolutionize patient screening and treatment. We aimed to evaluate the efficacy and reliability of a smartphone application, which utilizes camera-captured ECG images, in quantifying hyperkalemia risk compared to human experts.<br />Methods: We performed a retrospective analysis of ED hyperkalemic patients (serum potassium ≥ 6 mmol/L) and their age- and sex-matched non-hyperkalemic controls. The application was tested by five users and its performance was compared to five board-certified emergency physicians (EPs).<br />Results: Our study included 125 patients. The area under the curve (AUC)-receiver operating characteristic of the application's output was nearly identical among the users, ranging from 0.898 to 0.904 (median: 0.902), indicating almost perfect interrater agreement (Fleiss' kappa 0.948). The application demonstrated high sensitivity (0.797), specificity (0.934), negative predictive value (NPV) (0.815), and positive predictive value (PPV) (0.927). In contrast, the EPs showed moderate interrater agreement (Fleiss' kappa 0.551), and their consensus score had a significantly lower AUC of 0.662. The physicians' consensus demonstrated a sensitivity of 0.203, specificity of 0.934, NPV of 0.527, and PPV of 0.765. Notably, this performance difference remained significant regardless of patients' sex and age ( P < 0.001 for both).<br />Conclusion: Our findings suggest that a smartphone application can accurately and reliably quantify hyperkalemia risk using initial ECGs in the ED.<br />Competing Interests: Joonghee Kim, MD developed the algorithm and founded a start-up company ARPI Inc. He is the CEO of the company. Youngjin Cho works for the company as a research director. Eunkyoung Lee and Bumi Jeong work for the company as clinical researcher. Otherwise, there is no conflict of interest for the other authors.<br /> (© 2023 The Korean Academy of Medical Sciences.)

Details

Language :
English
ISSN :
1598-6357
Volume :
38
Issue :
45
Database :
MEDLINE
Journal :
Journal of Korean medical science
Publication Type :
Academic Journal
Accession number :
37987103
Full Text :
https://doi.org/10.3346/jkms.2023.38.e322