Bone density optimized pedicle screw insertion.

Authors :
Tsagkaris C
Calek AK
Fasser MR
Spirig JM
Caprara S
Farshad M
Widmer J
Source :
Frontiers in bioengineering and biotechnology [Front Bioeng Biotechnol] 2023 Oct 26; Vol. 11, pp. 1270522. Date of Electronic Publication: 2023 Oct 26 (Print Publication: 2023).
Publication Year :
2023

Abstract

Background: Spinal fusion is the most common surgical treatment for the management of degenerative spinal disease. However, complications such as screw loosening lead to painful pseudoarthrosis, and are a common reason for revision. Optimization of screw trajectories to increase implant resistance to mechanical loading is essential. A recent optimization method has shown potential for determining optimal screw position and size based on areas of high bone elastic modulus (E-modulus). Aim: The aim of this biomechanical study was to verify the optimization algorithm for pedicle screw placement in a cadaveric study and to quantify the effect of optimization. The pull-out strength of pedicle screws with an optimized trajectory was compared to that of a traditional trajectory. Methods: Twenty-five lumbar vertebrae were instrumented with pedicle screws (on one side, the pedicle screws were inserted in the traditional way, on the other side, the screws were inserted using an optimized trajectory). Results: An improvement in pull-out strength and pull-out strain energy of the optimized screw trajectory compared to the traditional screw trajectory was only observed for E-modulus values greater than 3500 MPa cm <superscript>3</superscript> . For values of 3500 MPa cm <superscript>3</superscript> or less, optimization showed no clear benefit. The median screw length of the optimized pedicle screws was significantly smaller than the median screw length of the traditionally inserted pedicle screws, p < 0.001. Discussion: Optimization of the pedicle screw trajectory is feasible, but seems to apply only to vertebrae with very high E-modulus values. This is likely because screw trajectory optimization resulted in a reduction in screw length and therefore a reduction in the implant-bone interface. Future efforts to predict the optimal pedicle screw trajectory should include screw length as a critical component of potential stability.<br />Competing Interests: MF reports being a Consultant for Incremed (Balgrist University Startup), Zimmer Biomet, Medacta, and 25 Segments (Balgrist Startup). All the other authors report no conflicts of interest.<br /> (Copyright © 2023 Tsagkaris, Calek, Fasser, Spirig, Caprara, Farshad and Widmer.)

Details

Language :
English
ISSN :
2296-4185
Volume :
11
Database :
MEDLINE
Journal :
Frontiers in bioengineering and biotechnology
Publication Type :
Academic Journal
Accession number :
37954015
Full Text :
https://doi.org/10.3389/fbioe.2023.1270522