Back to Search Start Over

Quantitative DECT of Iodine in Chronic Subdural Hematoma as Surrogate of Membrane Exudation: A Pilot Feasibility Study.

Authors :
Bodanapally UK
Aarabi B
Liang Y
Khalid M
Fleiter TR
Gandhi D
Source :
Journal of computer assisted tomography [J Comput Assist Tomogr] 2023 Nov-Dec 01; Vol. 47 (6), pp. 951-958. Date of Electronic Publication: 2023 Jul 22.
Publication Year :
2023

Abstract

Objective: We explore the feasibility to estimate the exudation from chronic subdural hematoma (CSDH) membranes, by using dual-energy computed tomography (DECT) quantification of iodine leak and test if the derived quantitative variables and membrane morphology correlates with hematoma volume, internal architecture (homogeneous, laminar, separated, and trabecular types), and fractional hyperdense hematoma at presentation.<br />Methods: In this retrospective study, consecutive CSDH patients with postcontrast DECT head images from January 2020 and June 2021 were analyzed. Predictor variables derived from DECT were correlated with outcome variables followed by mixed-effects regression analysis.<br />Results: The study included 36 patients with 50 observations (mean age, 72.6 years; standard deviation, 11.6 years); 31 were men. Dual-energy CT variables that correlated with hematoma volume were external membrane volume (ρ, 0.37; P = 0.008) and iodine concentration (ρ, -0.29; P = 0.04). Variables that correlated with separated type of hematoma were total iodine leak (median [Q 1 , Q 3 ], 68.3 mg [48.5, 88.9] vs 38.8 mg [15.5, 62.9]; P = 0.001) and iodine leak per unit membrane volume (median [Q 1 , Q 3 ], 16.47 mg/mL [10.19, 20.65] vs 8.68 mg/mL [5.72, 11.41]; P = 0.002). Membrane grade was the only variable that correlated with fractional hyperdense hematoma (ρ, 0.28; P = 0.05). Regression analysis showed total iodine leak as the strongest predictor of separated type hematoma (odds ratio [95% confidence interval], 1.06 per mg [1.01, 1.1]).<br />Conclusions: Dual-energy CT demonstrates iodine leak from CSDH membranes. The variables derived from DECT correlated with hematoma volume, internal architecture, and fractional hyperdense hematoma.<br />Competing Interests: The authors declare no conflict of interest.<br /> (Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1532-3145
Volume :
47
Issue :
6
Database :
MEDLINE
Journal :
Journal of computer assisted tomography
Publication Type :
Academic Journal
Accession number :
37948371
Full Text :
https://doi.org/10.1097/RCT.0000000000001501