Back to Search
Start Over
Vascular surgery study of the CGuard MicroNet-covered stent in patients with indication to carotid revascularization: POLGUARD.
- Source :
-
The Journal of cardiovascular surgery [J Cardiovasc Surg (Torino)] 2023 Dec; Vol. 64 (6), pp. 615-623. Date of Electronic Publication: 2023 Nov 10. - Publication Year :
- 2023
-
Abstract
- Background: In a recent randomized study, MicroNet-covered stent (CGuard) significantly reduced procedural and post-procedural cerebral embolism in relation to a single-layer CREST study carotid stent, but real-life clinical practice data are limited. The aim is to prospectively assess clinical outcomes of CGuard as a routine revascularization tool for patients with indication to carotid revascularization.<br />Methods: From April 2019 to November 2021, 204 elective patients (age 71.0±7.1years, 69.6% males, 21.7% symptomatic) were enrolled.<br />Results: Mean basal peak-systolic velocity was 251.41±91.85 cm/s with angiographic diameter stenosis 89.7±8.46%. About 34.4% lesions were severely calcified, 6.8% were angulated, and 4.4% showed significant access tortuosity. Access was femoral, with 100% protection device (filter) use. Two hundred and three lesions in 203 patients were treated (1 cross-over to surgery for lack of effective access, no cross-over to other devices); in most cases (66.9%) the stent was placed directly. For pre-dilated lesions, mean balloon diameter was 3.36±0.34mm. Mean nominal stent diameter was 7.64±0.5 mm; length was 37.19±4.5 mm. All stents were post-dilated (balloon diameter 5.2±0.25 mm). Residual stenosis was <30% in all (3.77±6.91%). By discharge, there were 2 minor strokes (0.9%) and one transient ischemic attack. By 30-days, one other minor stroke occurred in relation to de-novo atrial fibrillation. With no deaths or myocardial infarctions, 30-day total death/stroke/myocardial infarction rate was 1.48%. No in-stent thrombosis or patency loss occurred by 30-days. In-stent peak-systolic velocity was 55.49±22.73 cm/s.<br />Conclusions: Thirty-day results from POLGUARD study indicate safety and a low complication rate of the MicroNet-covered carotid stent use in every-day vascular surgery practice of carotid revascularization. Long-term observation is underway.
- Subjects :
- Male
Humans
Middle Aged
Aged
Female
Constriction, Pathologic complications
Treatment Outcome
Stents adverse effects
Vascular Surgical Procedures adverse effects
Carotid Stenosis complications
Carotid Stenosis diagnostic imaging
Carotid Stenosis surgery
Stroke etiology
Stroke prevention & control
Subjects
Details
- Language :
- English
- ISSN :
- 1827-191X
- Volume :
- 64
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- The Journal of cardiovascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 37947755
- Full Text :
- https://doi.org/10.23736/S0021-9509.23.12891-6