Back to Search
Start Over
Mini-augmented glenoid baseplate and mini-humeral tray reverse total shoulder arthroplasty implant comparisons: two-year clinical outcomes.
- Source :
-
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie [Eur J Orthop Surg Traumatol] 2024 Feb; Vol. 34 (2), pp. 1045-1056. Date of Electronic Publication: 2023 Oct 29. - Publication Year :
- 2024
-
Abstract
- Background: Augmented glenoid baseplate and offset humeral tray reverse total shoulder arthroplasty (RTSA) implants may decrease the mechanical impingement that creates scapular notching and improve shoulder function. This study evaluated the clinical efficacy of three different RTSA glenoid baseplate and offset humeral tray combinations for patient-reported shoulder function, pain and instability, radiographic imaging evidence of glenoid baseplate or humeral stem subsidence and migration, bony changes associated with implant loosening, and scapular notching over the initial 2 years post-RTSA. Primary outcomes included active shoulder mobility, perceived function, pain, instability, scapular notching, and implant survival.<br />Methods: Sixty-seven patients from 6 research sites received one of three different glenoid baseplate and humeral tray combinations. Group 1 (n = 21) received a mini-augmented glenoid baseplate with a standard humeral tray; Group 2 (n = 23) received a standard glenoid baseplate and a mini-humeral tray with 3 trunnion offset options; Group 3 (n = 23) received both a mini-augmented glenoid baseplate and a mini-humeral tray with 3 trunnion offset options. Subjects underwent radiologic evaluation, completed the ASES scale, the EQ-5D-5L quality of life scale, VAS shoulder pain and instability questions, and active shoulder mobility measurements pre-operatively, and 6-weeks, 6-months, 1-2 years post-RTSA.<br />Results: Improved active shoulder mobility, quality of life, perceived function, decreased shoulder pain and instability, excellent implant survival and minimal scapular notching were observed for all groups. Group 3 had better overall active shoulder mobility than the other groups and better perceived function than Group 1.<br />Conclusion: The group that received the mini-augmented glenoid baseplate and mini-humeral tray combination had better overall active shoulder flexion, external rotation at 90° abduction, and internal rotation. This group also had better perceived shoulder function compared to the group that received a mini-augmented glenoid baseplate with a standard humeral tray.<br /> (© 2023. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.)
- Subjects :
- Humans
Shoulder Pain surgery
Quality of Life
Humerus surgery
Treatment Outcome
Range of Motion, Articular
Retrospective Studies
Arthroplasty, Replacement, Shoulder
Shoulder Joint diagnostic imaging
Shoulder Joint surgery
Joint Prosthesis adverse effects
Shoulder Prosthesis
Glenoid Cavity surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1432-1068
- Volume :
- 34
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- European journal of orthopaedic surgery & traumatology : orthopedie traumatologie
- Publication Type :
- Academic Journal
- Accession number :
- 37898968
- Full Text :
- https://doi.org/10.1007/s00590-023-03757-x