Back to Search
Start Over
Effects of Breathing Patterns on Amide Proton Transfer MRI in the Kidney: A Preliminary Comparative Study in Healthy Volunteers and Patients With Tumors.
- Source :
-
Journal of magnetic resonance imaging : JMRI [J Magn Reson Imaging] 2024 Jul; Vol. 60 (1), pp. 222-230. Date of Electronic Publication: 2023 Oct 27. - Publication Year :
- 2024
-
Abstract
- Background: The amide proton transfer-weighted (APTw) imaging for kidney diseases is important. However, the breathing patterns on APTw imaging remains unexplored.<br />Purpose: This study aimed to investigate the effects of intermittent breath-hold (IBH) and free breathing (FB) on renal 3D-APTw imaging.<br />Study Type: Healthy volunteers were enrolled prospectively, and renal clear cell carcinoma (RCCC) patients were included retrospectively.<br />Population: 58 healthy volunteers and 10 RCCC patients.<br />Field Strength/sequence: 3-T, turbo spin echo, and fast field echo.<br />Assessment: 3D-APTw imaging was scanned using the IBH and FB methods in volunteers and using the IBH method in RCCC patients. The image quality was evaluated by three observers according to the 5-point Likert scale. Optimal images rated at three points or higher were used to measure the APT values.<br />Statistical Analysis: The measurement repeatability was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The APT values were analyzed using McNemar's test, one-way analysis of variance, and t test.<br />Results: 50 healthy volunteers and 8 RCCC patients were enrolled. Renal 3D-APTw imaging using the IBH method revealed a higher success rate (88% vs 78%). The ICCs were excellent in the IBH group (ICCs > 0.74) and were good in the FB group (ICCs < 0.74). No significant differences in the APT values among various zones using the IBH (P = 0.263) or FB method (P = 0.506). The mean APT value using the IBH method (2.091% ± 0.388%) was slightly lower than the FB method (2.176% ± 0.292%), but no significant difference (P = 0.233). The APT value of RCCC (4.832% ± 1.361%) was considerably higher than normal renal using the IBH method.<br />Conclusions: The study demonstrated that the IBH method substantially increased the image quality of renal 3D-APTw imaging. Furthermore, APT values may vary between normal and tumor tissues.<br />Level of Evidence: 2 TECHNICAL EFFICACY: Stage 2.<br /> (© 2023 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.)
- Subjects :
- Humans
Male
Female
Middle Aged
Adult
Reproducibility of Results
Prospective Studies
Aged
Imaging, Three-Dimensional
Retrospective Studies
Amides
Breath Holding
Young Adult
Image Processing, Computer-Assisted methods
Kidney Neoplasms diagnostic imaging
Magnetic Resonance Imaging methods
Healthy Volunteers
Carcinoma, Renal Cell diagnostic imaging
Kidney diagnostic imaging
Protons
Respiration
Subjects
Details
- Language :
- English
- ISSN :
- 1522-2586
- Volume :
- 60
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of magnetic resonance imaging : JMRI
- Publication Type :
- Academic Journal
- Accession number :
- 37888865
- Full Text :
- https://doi.org/10.1002/jmri.29099