Back to Search
Start Over
Column-free optical deconvolution of intrinsic fluorescence for a monoclonal antibody and its product-related impurities.
- Source :
-
Journal of chromatography. A [J Chromatogr A] 2023 Nov 22; Vol. 1711, pp. 464463. Date of Electronic Publication: 2023 Oct 18. - Publication Year :
- 2023
-
Abstract
- The quantification of monoclonal antibody (mAb) aggregates and fragments using high pressure liquid chromatography-size exclusion chromatography (HPLC-SEC) typically requires off-line measurements that are time-consuming and therefore not compatible with real-time monitoring. However, it has been crucial to manufacturing and process development, and remains the industrial standard in the assessment of product-related impurities. Here we demonstrate that our previously established intrinsic time-resolved fluorescence (TRF) approach can be used to quantify the bioprocess critical quality attribute (CQA) of antibody product purity at various stages of a typical downstream process, with the potential to be developed for in-line bioprocess monitoring. This was directly benchmarked against industry-standard HPLC-SEC. Strong linear correlations were observed between outputs from TRF spectroscopy and HPLC-SEC, for the monomer and aggregate-fragment content, with R <superscript>2</superscript> coefficients of 0.99 and 0.69, respectively. At total protein concentrations above 1.41 mg/mL, HPLC-SEC UV-Vis chromatograms displayed signs of detector saturation which reduced the accuracy of protein quantification, thus requiring additional sample dilution steps. By contrast, TRF spectroscopy increased in accuracy at these concentrations due to higher signal-to-noise ratios. Our approach opens the potential for reducing the time and labour required for validating aggregate content in mAb bioprocess stages from the several hours required for HPLC-SEC to a few minutes per sample.<br />Competing Interests: Declaration of Competing Interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: J.E.H. and P.A.D. are co-authors on a patent application which could increase in value if the methods and ideas described in this paper find widespread application.<br /> (Copyright © 2023 The Author(s). Published by Elsevier B.V. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1873-3778
- Volume :
- 1711
- Database :
- MEDLINE
- Journal :
- Journal of chromatography. A
- Publication Type :
- Academic Journal
- Accession number :
- 37866332
- Full Text :
- https://doi.org/10.1016/j.chroma.2023.464463