Biokinetic model analysis with DTPA administration for a case of accidental inhalation of actinides in Japan.
- Source :
-
Radiation protection dosimetry [Radiat Prot Dosimetry] 2023 Oct 11; Vol. 199 (15-16), pp. 2025-2029. - Publication Year :
- 2023
-
Abstract
- Accidental inhalation intake of plutonium isotopes and 241Am occurred at a Pu research facility in Japan in 2017, and the five workers involved in this accident were treated by the administration of Ca/Zn-diethylenetriaminepentaacetic acid (DTPA). For the worker who was most internally exposed, the therapy was continued over 1 y after the accident. Urinary samples collected before and after each administration were subject to bioassay to evaluate the efficacy of the dose reduction. This study performed numerical analyses using a biokinetic model dealing with 241Am-DTPA with reference to the European Coordinated Network on Radiation Dosimetry approach, which assumes that the complex of actinides and Ca/Zn-DTPA is generated in the designated compartments in the biokinetic model. The results of the model prediction well captured the trend of the observed urinary excretion in the long-term bioassay and would be useful to evaluate the efficacy of the Ca/Zn-DTPA administration for the worker involved in the accident.<br /> (© The Author(s) 2023. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.)
Details
- Language :
- English
- ISSN :
- 1742-3406
- Volume :
- 199
- Issue :
- 15-16
- Database :
- MEDLINE
- Journal :
- Radiation protection dosimetry
- Publication Type :
- Academic Journal
- Accession number :
- 37819312
- Full Text :
- https://doi.org/10.1093/rpd/ncac224