Back to Search
Start Over
Endoscopic impedance planimetry versus high-resolution manometry (HRM) for pre-operative motility evaluation in anti-reflux surgery.
- Source :
-
Surgical endoscopy [Surg Endosc] 2024 Jan; Vol. 38 (1), pp. 377-383. Date of Electronic Publication: 2023 Oct 06. - Publication Year :
- 2024
-
Abstract
- Introduction: Pre-operative evaluation of patients with gastroesophageal reflux disease (GERD) includes assessment of esophageal motility. High-resolution manometry (HRM) is the gold standard; endoscopic impedance planimetry (IP) with Endoflip 2.0 is increasingly utilized in esophageal disorders of motility. We hypothesized that normal IP motility would correlate with normal HRM motility and tested this in a prospective cohort study.<br />Methods: Patients presenting for surgical evaluation of GERD between 9/2020 and 10/2021 were prospectively enrolled under an IRB-approved protocol. Patients with prior esophageal/gastric surgery, known motility disorders, or large paraesophageal hernias were excluded. All underwent HRM and IP, with normal motility defined by Chicago 3.0 classification for HRM and the presence of repetitive antegrade contractions for IP. Logistic regression and t test were used to analyze the data; p value < 0.05 was considered significant.<br />Results: Of 63 patients enrolled, 48 completed both IP and HRM testing. The cohort was 50% male with a median age of 52.5 [42.0, 66.0] years, mostly ASA class 1-2 (75.1%, n = 36) and had an average BMI of 31.4 ± 6.3 kg/m <superscript>2</superscript> . Normal motility tracings were in 62.5% of IP and 75% of HRM tests. Using HRM as the gold standard, IP detected normal motility with a sensitivity of 65.8% and a specificity of 50% (positive predictive value 83.3%, negative predictive value 27.8%). Normal IP was not statistically significant in predicting normal HRM (OR 3.182, 95% CI 0.826-12.262, p = 0.0926). Tolerability of IP was significantly better than HRM with lower rates of discomfort (10.9% vs. 93.4%, p < 0.0001) and higher willingness to repeat testing (100% vs. 47.8%, p < 0.0001).<br />Conclusion: Esophageal motility testing with Endoflip 2.0 is well tolerated by patients. The low specificity (50%), poor negative predictive value (27.8%), and lack of statistically significant concordance between IP and HRM raises concern for the reliability of this test as a stand-alone replacement for HRM in the pre-operative evaluation for GERD.<br /> (© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)
Details
- Language :
- English
- ISSN :
- 1432-2218
- Volume :
- 38
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Surgical endoscopy
- Publication Type :
- Academic Journal
- Accession number :
- 37803186
- Full Text :
- https://doi.org/10.1007/s00464-023-10418-x