Sliding on cortical shell: Biomechanical characterization of the vertebral cannulation for pedicle screw insertion.

Authors :
Leblond L
Godio-Raboutet Y
Tomi F
Glard Y
La Greca R
Clement T
Evin M
Source :
Clinical biomechanics (Bristol, Avon) [Clin Biomech (Bristol, Avon)] 2023 Dec; Vol. 110, pp. 106102. Date of Electronic Publication: 2023 Sep 22.
Publication Year :
2023

Abstract

Background: Pedicular screws pull-out has been well studied unlike their insertion. A need for characterizing cannulation before pedicle screw implantation is highlighted in literature and offers promising prospects for future intra-operation instrumentation. A reliable cannulation protocol for ex-vivo testing in swine and cadaver vertebrae is presented in this work to predict extra pedicular perforation.<br />Methods: An MTS Acumen 3 A/T electrodynamic device, with a tri-axis 3 kN Kistler load cell mounted on a surgical tool was used to reproduce surgeon's gesture by moving at a constant rotational speed of 10°/mm and performing a three-section test. Perforation of the pedicle's cortical shell was planned through a design of experiment on the surgical tool angle at the entry point. Samples were scanned before and after mechanical tests and reproducibility of the protocol was tested on synthetic foam. Computation of the angle between cannulation tool and pedicle cortical shell was performed as well as cannulation coefficient of each perforation section.<br />Findings: A total of 68 pedicles were tested: 19 perforated and 21 non-perforated human pedicles, 17 perforated and 16 non-perforated swine pedicles. The reproducibility of the protocol for cannulation coefficient computation resulted in an intraclass correlation coefficient of 0.979. Cannulation coefficients results presented variability within spinal levels as well as between swine and human model. Correlation between bone density and cannulation coefficient was found significant (p < 0.005). Torque measurement was found to be the best predictor of perforation. Threshold of angle for prediction of perforation was found to be 21.7°.<br />Interpretation: Characterizing pedicle cannulation enables to predict extra pedicular perforation. Influence of bone mineral density and patient-specific morphology on pedicle cannulation has been highlighted together with a comparison of swine and cadaver models.<br />Competing Interests: Declaration of Competing Interest The authors have no financial and personal relationships with other people or organizations that could inappropriately influence (bias) their work.<br /> (Copyright © 2023 Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1879-1271
Volume :
110
Database :
MEDLINE
Journal :
Clinical biomechanics (Bristol, Avon)
Publication Type :
Academic Journal
Accession number :
37769380
Full Text :
https://doi.org/10.1016/j.clinbiomech.2023.106102