Back to Search
Start Over
Robot-Assisted Renal Surgery with the New Hugo Ras System: Trocar Placement and Docking Settings.
- Source :
-
Journal of personalized medicine [J Pers Med] 2023 Sep 13; Vol. 13 (9). Date of Electronic Publication: 2023 Sep 13. - Publication Year :
- 2023
-
Abstract
- The current literature relating to the novel Hugo <superscript>TM</superscript> RAS System lacks consistent data concerning the bedside features of robot-assisted partial nephrectomy (RAPN). To describe the trocar placement and docking settings for RAPN with a three-arm configuration to streamline the procedure with Hugo <superscript>TM</superscript> RAS, between October 2022 and April 2023, twenty-five consecutive off-clamp RAPNs for renal tumors with the Hugo <superscript>TM</superscript> RAS System were performed. We conceived a trouble-free three-arm setting to ease and standardize RAPN trocar placement and docking settings with Hugo <superscript>TM</superscript> RAS. Perioperative data were collected. Post-operative complications were reported according to the Clavien-Dindo classification. The eGFR was calculated according to the CKD-EPI formula. Continuous variables were presented as the median and IQR, while frequencies were reported as categorical variables. Off-clamp RAPNs were successfully performed in all cases without the need for conversion or additional port placement. The median age and BMI were 69 years (IQR, 60-73) and 27.3 kg/m <superscript>2</superscript> (IQR, 25.7-28.1), respectively. The median tumor size and R.E.N.A.L. score were 32.5 mm (IQR, 26-43.7) and 6 (IQR, 5-7), respectively. Two patients were affected by cT2 renal tumors. The median docking and console time were 5 (IQR, 5-6) and 90 min (IQR, 68-135.75 min), respectively, with slightly progressive improvements in the docking time achieved. No intraoperative complications occurred alongside clashes between instruments or with the bed assistant. In experienced hands, this simplified three-instrument configuration of the Hugo <superscript>TM</superscript> RAS System for off-clamp RAPN resulted in feasible and safe practice, providing patient-tailored trocar placement and docking with non-inferior peri-perioperative outcomes to other robotic platforms.
Details
- Language :
- English
- ISSN :
- 2075-4426
- Volume :
- 13
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Journal of personalized medicine
- Publication Type :
- Academic Journal
- Accession number :
- 37763140
- Full Text :
- https://doi.org/10.3390/jpm13091372