Back to Search
Start Over
Device trueness in passivity and misfit of CAD-CAM frameworks: Conventional versus printed casts.
- Source :
-
The Journal of prosthetic dentistry [J Prosthet Dent] 2023 Sep 23. Date of Electronic Publication: 2023 Sep 23. - Publication Year :
- 2023
- Publisher :
- Ahead of Print
-
Abstract
- Statement of Problem: Obtaining a passive and well-adapted framework is challenging when intraoral scanning edentulous arches with multiple implants. The trueness of the printed casts is unclear.<br />Purpose: The purpose of this clinical study was to evaluate the trueness of frameworks made from conventional and printed casts regarding clinical passivity and misfit.<br />Material and Methods: Ten participants with complete mandibular fixed implant-supported interim prostheses retained by 4 implants were included. Each participant had a conventional impression and a digital scan made. The digital scan was made using an innovative device. Both conventional and digital casts were made, and the virtual images were used for milling the digital framework in cobalt chromium alloy. All frameworks were evaluated for passivity and marginal vertical misfit with the single screw test, with 4 attempts consisting of the tightened screw position, a test with all screws tightened, and an interspersed tightening test. The Kruskal-Wallis test was used to evaluate the trueness of the tested device for framework construction through the single screw test on vertical marginal misfit in the conventional and printed groups (α=.008). The Friedman test was used to assess the effect of test type (α=.05), and the Wilcoxon test was used to identify group-to-group differences (α=.017).<br />Results: The absence of space between the framework and the abutments and interferences during its placement, as well as good stability, were observed clinically. In laboratory analysis, greater framework misfits were observed in the printed group compared with the conventional group when the single screw test was applied. Comparing the 3 tests used, the greatest misfits were observed when the framework was screwed onto the printed cast.<br />Conclusions: The innovative device tested for the intraoral scanning of multiple implants had clinically acceptable accuracy for the construction of passive and adapted frameworks. The conventional cast was more accurate than the printed cast, with lower misfit values, in all tests.<br /> (Copyright © 2023 Editorial Council for The Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1097-6841
- Database :
- MEDLINE
- Journal :
- The Journal of prosthetic dentistry
- Publication Type :
- Academic Journal
- Accession number :
- 37748995
- Full Text :
- https://doi.org/10.1016/j.prosdent.2023.07.039