Back to Search
Start Over
A review of latrine front-end characteristics associated with microbial infection risk; reveals a lack of pathogen density data.
- Source :
-
International journal of hygiene and environmental health [Int J Hyg Environ Health] 2023 Sep; Vol. 254, pp. 114261. Date of Electronic Publication: 2023 Sep 20. - Publication Year :
- 2023
-
Abstract
- Unsafe sanitation accounts for an estimated 898,000 global deaths annually. The faecal pathogen transmission pathway is complex with several possible routes. Latrine front-end characteristics and usage behaviours are one key transmission pathway for microbial pathogens, however, there has not yet been a synthesis of the available research. This review aims to compare the microbial infection risks with latrine front-end components including any quantified microbial densities within the household latrines. This review was conducted with no restriction on the geographical location of the research. Of 118 studies reviewed, only ten (8%) have quantified the microbial density inside the household latrines compared to 109 (92%) measuring the infection risks. The reported risks were most frequent for specific bacterial (n = 34), and helminths infections (n = 32) compared to diarrhoea (n = 23), combined (n = 15), protozoan (n = 4), and viral (n = 4) infections. The infections risk decreased for using latrines lying at a higher position on the sanitation ladder (for example flush latrines) compared to those lying lower (for example pit latrines). The trend was similar for using floor materials that were easier to clean and less favourable for pathogen survival inside the latrines (for example, concrete as opposed to earth). Faecal coliforms were reported highest on the surface of the squat pan (743 CFU/cm <superscript>2</superscript> ) of pour-flush latrines and helminths on earth floors of pit latrines (1.5 eggs and larvae per gram of soil). Irrespective of latrine type and its position on the sanitation ladder, a dirty latrine, evidenced by a visible lack of cleanliness, significantly increased the risk for all infections. This study recommends that effective microbial infection risk reduction in latrines can be gained efficiently by ensuring washable surfaces and consistent cleaning practices. Future studies should include more rigorous measurements of microbial densities in various latrine types incorporating the different front-end components and usage behaviours.<br />Competing Interests: Declaration of competing interest None.<br /> (Copyright © 2023 The Authors. Published by Elsevier GmbH.. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1618-131X
- Volume :
- 254
- Database :
- MEDLINE
- Journal :
- International journal of hygiene and environmental health
- Publication Type :
- Academic Journal
- Accession number :
- 37734133
- Full Text :
- https://doi.org/10.1016/j.ijheh.2023.114261