Measuring ADAMTS-13 activity to diagnose thrombotic thrombocytopenic purpura: a novel, fast fiber-optic surface plasmon resonance immunoassay.

Authors :
Bonnez Q
Dekimpe C
Tellier E
Kaplanski G
Verhamme P
Tersteeg C
De Meyer SF
Lammertyn J
Joly B
Coppo P
Veyradier A
Vanhoorelbeke K
Source :
Research and practice in thrombosis and haemostasis [Res Pract Thromb Haemost] 2023 Aug 19; Vol. 7 (6), pp. 102171. Date of Electronic Publication: 2023 Aug 19 (Print Publication: 2023).
Publication Year :
2023

Abstract

Background: Thrombotic thrombocytopenic purpura (TTP) is characterized by severe ADAMTS-13 activity deficiency (<10%). Diagnostic testing is challenging because of unavailability, high cost, and expert technician requirement of ADAMTS-13 enzyme assays. Cost-effective, automated fiber-optic surface plasmon resonance (FO-SPR) platforms show potential for developing diagnostic tests. Yet, FO-SPR has never been explored to measure enzymatic activities.<br />Objectives: To develop an easy-to-use ADAMTS-13 activity assay utilizing optical fibers to rapidly diagnose TTP.<br />Methods: The ADAMTS-13 activity assay was designed and optimized using FO-SPR technology based on a previously described enzyme-linked immunosorbent assay setup. A calibration curve was generated to quantify ADAMTS-13 activity in plasma of healthy donors and patients with acute immune-mediated TTP (iTTP), hemolytic uremic syndrome, or sepsis. ADAMTS-13 activity data from FO-SPR and fluorescence resonance energy transfer-based strategies (FRETS)-VWF73 reference assays were compared.<br />Results: After initial assay development, optimization improved read-out magnitude and signal-to-noise ratio and reduced variation. Further characterization demonstrated a detection limit (6.8%) and inter-assay variation (Coefficient of variation, 7.2%) that showed good analytical sensitivity and repeatability. From diverse plasma samples, only plasma from patients with acute iTTP showed ADAMTS-13 activities below 10%. Strong Pearson correlation ( r  = 0.854) between FO-SPR and reference FRETS-VWF73 assays were observed for all measured samples.<br />Conclusions: A fast ADAMTS-13 activity assay was designed onto automated FO-SPR technology. Optimization resulted in sensitive ADAMTS-13 activity measurements with a detection limit enabling clinical diagnosis of TTP within 3 hours. The FO-SPR assay proved strong correlation with the reference FRETS-VWF73 assay. For the first time, this assay demonstrated the capacity of FO-SPR technology to measure enzymatic activity in pre-clinical context.<br /> (© 2023 The Author(s).)

Details

Language :
English
ISSN :
2475-0379
Volume :
7
Issue :
6
Database :
MEDLINE
Journal :
Research and practice in thrombosis and haemostasis
Publication Type :
Academic Journal
Accession number :
37711907
Full Text :
https://doi.org/10.1016/j.rpth.2023.102171