Development of an in-vitro model for extracorporeal blood pumps to study the effects of artificial pulsatility on human blood.

Authors :
Zieger B
Schneider D
Brixius SJ
Scherer C
Buchwald A
Trummer G
Czerny M
Beyersdorf F
Busch HJ
Benk C
Pooth JS
Source :
Frontiers in medicine [Front Med (Lausanne)] 2023 Aug 28; Vol. 10, pp. 1237002. Date of Electronic Publication: 2023 Aug 28 (Print Publication: 2023).
Publication Year :
2023

Abstract

Introduction: The application of extracorporeal circulation (ECC) systems is known to be associated with several implications regarding hemolysis, inflammation, and coagulation. In the last years, systems with pulsatile blood flow are increasingly used with the intention to improve hemodynamics in reperfusion. However, their implications on the aforementioned aspects remain largely unknown. To investigate the effects of pulsatility, this ex-vivo study was initiated.<br />Methods: Test circuits (primed with human whole blood) were set up in accordance with the recommendations of international standards for in-vitro evaluation of new components and systems of ECC. Diagonal pumps were either set up with non-pulsatile (n = 5, NPG) or pulsatile (n = 5, PG) pump settings and evaluated for 6 h. All analyses were conducted with human whole blood. Blood samples were repeatedly drawn from the test circuits and analyzed regarding free hemoglobin, interleukin 8 (IL-8), platelet aggregation and acquired von Willebrand syndrome (AVWS).<br />Results: After 1 h of circulation, a significant coagulation impairment (impaired platelet function and AVWS) was observed in both groups. After 6 h of circulation, increased IL-8 concentrations were measured in both groups (NPG: 0.05 ± 0.03 pg./mL, PG: 0.03 ± 0.01 pg./mL, p  = 0.48). Pulsatile pump flow resulted in significantly increased hemolysis after 6 h of circulation (NPG: 37.3 ± 12.4 mg/100 L; PG: 59.6 ± 14.5 mg/100 L; p  < 0.05).<br />Conclusion: Our results indicate that the coagulative impairment takes place in the early phase of ECC. Pulsatility did not affect the occurrence of AVWS ex-vivo . Prolonged durations of pulsatile pump flow led to increased hemolysis and therefore, its prolonged use should be employed cautiously in clinical practice with appropriate monitoring.<br />Competing Interests: FB is founder and shareholder and CB, and GT are shareholders of Resuscitec GmbH, Freiburg, Germany, which is a start-up company from the University Medical Centre Freiburg. CB, J-SP, SB and CS are part-time employees of Resuscitec GmbH, Freiburg, Germany. The remaining author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2023 Zieger, Schneider, Brixius, Scherer, Buchwald, Trummer, Czerny, Beyersdorf, Busch, Benk and Pooth.)

Details

Language :
English
ISSN :
2296-858X
Volume :
10
Database :
MEDLINE
Journal :
Frontiers in medicine
Publication Type :
Academic Journal
Accession number :
37711739
Full Text :
https://doi.org/10.3389/fmed.2023.1237002