Back to Search Start Over

Stability Study and Handling Recommendations for Multiresidue Pesticide Mixes under Diverse Storage Conditions for LC-MS/MS and GC-MS/MS.

Authors :
Wiest LA
Hepner JR
Fisher JE
Risha KM
Lidgett JH
Ballarotto VN
Konschnik JD
Source :
Journal of AOAC International [J AOAC Int] 2023 Nov 02; Vol. 106 (6), pp. 1550-1563.
Publication Year :
2023

Abstract

Background: In response to the growing global need for pesticide residue testing, laboratories must develop versatile analytical methods and workflows to produce scientifically sound results. One of the many challenges faced by food chemists is acquiring suitable pesticide certified reference materials (CRMs) to calibrate analytical equipment, monitor method performance, and confirm the identity and concentration of hundreds of pesticide residues in food samples. CRM producers invest considerable resources to ensure the stability of their products.<br />Objective: To present proper CRM handling and storage practices as guidance to ensure stability based on the results of several multiresidue pesticide stability studies.<br />Methods: The open ampoule and combined multiresidue mix studies were conducted under controlled conditions. New ampoules containing multiresidue pesticide CRM mixtures were opened and compared to previously opened ampoules at multiple intervals while stored under freezing and refrigerated temperatures. Both LC- and GC-amenable pesticides (>200 residues) were combined and stored under typical laboratory conditions. Studies were performed with and without celery matrix.<br />Results: The open ampoule study showed high levels of stability for all mixtures. All GC residues remained stable over the duration of the experiment. A week after opening LC multiresidue pesticide mixtures showed minor degradation. After combination of the multiresidue pesticide mixtures, degradation occurred rapidly for both the GC and LC mixtures.<br />Conclusion: Multiresidue pesticide mixtures are stable as ampullated until they are opened. Once the contents of a kit were opened and combined, decreasing stability was observed over time. This was true for both the LC and GC kits. Working mixtures of CRMs for instrument calibration should be made daily.<br />Highlights: This article shows a novel approach for measuring stability of CRM mixes. In-depth analysis of multiresidue pesticide mixtures and the stability that can be expected before and after mixing under typical storage conditions is described.<br /> (© The Author(s) 2023. Published by Oxford University Press on behalf of AOAC INTERNATIONAL.)

Details

Language :
English
ISSN :
1944-7922
Volume :
106
Issue :
6
Database :
MEDLINE
Journal :
Journal of AOAC International
Publication Type :
Academic Journal
Accession number :
37701991
Full Text :
https://doi.org/10.1093/jaoacint/qsad096