Back to Search Start Over

Targeted left ventricular lead positioning to the site of latest activation in cardiac resynchronization therapy: a systematic review and meta-analysis.

Authors :
Fyenbo DB
Bjerre HL
Frausing MHJP
Stephansen C
Sommer A
Borgquist R
Bakos Z
Glikson M
Milman A
Beinart R
Kockova R
Sedlacek K
Wichterle D
Saba S
Jain S
Shalaby A
Kronborg MB
Nielsen JC
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2023 Aug 02; Vol. 25 (9).
Publication Year :
2023

Abstract

Aims: Several studies have evaluated the use of electrically- or imaging-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT) recipients. We aimed to assess evidence for a guided strategy that targets LV lead position to the site of latest LV activation.<br />Methods and Results: A systematic review and meta-analysis was performed for randomized controlled trials (RCTs) until March 2023 that evaluated electrically- or imaging-guided LV lead positioning on clinical and echocardiographic outcomes. The primary endpoint was a composite of all-cause mortality and heart failure hospitalization, and secondary endpoints were quality of life, 6-min walk test (6MWT), QRS duration, LV end-systolic volume, and LV ejection fraction. We included eight RCTs that comprised 1323 patients. Six RCTs compared guided strategy (n = 638) to routine (n = 468), and two RCTs compared different guiding strategies head-to-head: electrically- (n = 111) vs. imaging-guided (n = 106). Compared to routine, a guided strategy did not significantly reduce the risk of the primary endpoint after 12-24 (RR 0.83, 95% CI 0.52-1.33) months. A guided strategy was associated with slight improvement in 6MWT distance after 6 months of follow-up of absolute 18 (95% CI 6-30) m between groups, but not in remaining secondary endpoints. None of the secondary endpoints differed between the guided strategies.<br />Conclusion: In this study, a CRT implantation strategy that targets the latest LV activation did not improve survival or reduce heart failure hospitalizations.<br />Competing Interests: Conflict of interest: M.H.J.P.F. has received consulting fees from Medtronic outside the submitted work. C.S. has attended European Heart Rhythm Association (EHRA) device-exam preparatory courses held by Biotronik and Boston Scientific. S.S. has received research support from Abbott and Boston Scientific and Advisory Board work from Medtronic and Boston Scientific. J.C.N. received grants from the Novo Nordisk Foundation outside this work and is executive editor of Europace. All other authors declare no conflicts of interest.<br /> (© The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology.)

Details

Language :
English
ISSN :
1532-2092
Volume :
25
Issue :
9
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
37695316
Full Text :
https://doi.org/10.1093/europace/euad267