Congo Red Staining in Digital Pathology: The Streamlined Pipeline for Amyloid Detection Through Congo Red Fluorescence Digital Analysis.

Authors :
Cazzaniga G
Bolognesi MM
Stefania MD
Mascadri F
Eccher A
Alberici F
Mescia F
Smith A
Fraggetta F
Rossi M
Gambaro G
Pagni F
L'Imperio V
Source :
Laboratory investigation; a journal of technical methods and pathology [Lab Invest] 2023 Nov; Vol. 103 (11), pp. 100243. Date of Electronic Publication: 2023 Aug 25.
Publication Year :
2023

Abstract

Renal amyloidosis is a rare condition caused by the progressive accumulation of misfolded proteins within glomeruli, vessels, and interstitium, causing functional decline and requiring prompt treatment due to its significant morbidity and mortality. Congo red (CR) stain on renal biopsy samples is the gold standard for diagnosis, but the need for polarized light is limiting the digitization of this nephropathology field. This study explores the feasibility and reliability of CR fluorescence on virtual slides (CRFvs) in evaluating the diagnostic accuracy and proposing an automated digital pipeline for its assessment. Whole-slide images from 154 renal biopsies with CR were scanned through a Texas red fluorescence filter (NanoZoomer S60, Hamamatsu) at the digital Nephropathology Center of the Istituto di Ricovero e Cura a Carattere Scientifico San Gerardo, Monza, Italy, and evaluated double-blinded for the detection and quantification through the amyloid score and a custom ImageJ pipeline was built to automatically detect amyloid-containing regions. Interobserver agreement for CRFvs was optimal (k = 0.90; 95% CI, 0.81-0.98), with even better concordance when consensus-based CRFvs evaluation was compared to the standard CR birefringence (BR) (k = 0.98; 95% CI, 0.93-1). Excellent performance was achieved in the assessment of amyloid score overall by CRFvs (weighted k = 0.70; 95% CI, 0.08-1), especially within the interstitium (weighted k = 0.60; 95% CI, 0.35-0.84), overcoming the misinterpretation of interstitial and capsular collagen BR. The application of an automated digital pathology pipeline (Streamlined Pipeline for Amyloid detection through CR fluorescence Digital Analysis, SPADA) further increased the performance of pathologists, leading to a complete concordance with the standard BR. This study represents an initial step in the validation of CRFvs, demonstrating its general reliability in a digital nephropathology center. The computational method used in this study has the potential to facilitate the integration of spatial omics and artificial intelligence tools for the diagnosis of amyloidosis, streamlining its detection process.<br /> (Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1530-0307
Volume :
103
Issue :
11
Database :
MEDLINE
Journal :
Laboratory investigation; a journal of technical methods and pathology
Publication Type :
Academic Journal
Accession number :
37634845
Full Text :
https://doi.org/10.1016/j.labinv.2023.100243