Back to Search Start Over

Toward the rapid diagnosis of sepsis: dendritic copper nanostructure functionalized diazonium salt modified screen-printed graphene electrode for IL-6 detection.

Authors :
Jesadabundit W
Jampasa S
Crapnell RD
Dempsey NC
Banks CE
Siangproh W
Chailapakul O
Source :
Mikrochimica acta [Mikrochim Acta] 2023 Aug 23; Vol. 190 (9), pp. 362. Date of Electronic Publication: 2023 Aug 23.
Publication Year :
2023

Abstract

Sepsis, an infectious disease affecting millions of people's health worldwide each year, calls for urgent attention to an improvement of analytical devices. Chemiluminescence immunoassay is a typical diagnostic method utilized to assess the risk development of sepsis. However, due to its high-cost, delayed, and complicated procedure, the practical utilization is therefore undoubtedly limited, especially for point-of-care test. Herein, we fabricated for the first time an immunosensor based on dendritic copper nanostructures (CuNSs) combined with 4-aminobenzoic acid (4-AB, the diazonium salt) as antibody linker modified on a screen-printed graphene electrode for the early detection of the sepsis biomarker interleukin-6 (IL-6). The electrode fabrication is made by electrodeposition, thus eliminating the multistep of nanomaterial synthesis and time wasting. The resulting dendritic CuNSs significantly increase the effective surface area (1.2 times) and the sensor's performance. The morphology of this combination was characterized using CV, EIS, SEM, EDX, and FTIR techniques. In the detection process, the appearance of IL-6 suppresses the current response of the redox probe indicator measured by differential pulse voltammetry due to the antibody-antigen complex. The subtraction of signal (ΔI) was interpreted as IL-6 concentration. This sensor exhibited a linear range from 0.05 to 500 pg mL <superscript>-1</superscript> with low detection limit of 0.02 pg mL <superscript>-1</superscript> , proving a possibility for early sepsis screening. In addition, the established immunosensor can successfully quantify IL-6 in human serum sample, in which the results agreed well with those achieved using the standard approach, further showing high practical applicability of this developed immunosensor.<br /> (© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.)

Details

Language :
English
ISSN :
1436-5073
Volume :
190
Issue :
9
Database :
MEDLINE
Journal :
Mikrochimica acta
Publication Type :
Academic Journal
Accession number :
37608141
Full Text :
https://doi.org/10.1007/s00604-023-05939-0