Back to Search Start Over

Static compression and fatigue behavior of heat-treated selective laser melted titanium alloy (Ti6Al4V) gyroid cylinders.

Authors :
Hitchon S
Anderson W
Milner JS
Hong G
Ivanov T
Willing R
Holdsworth D
Source :
Journal of the mechanical behavior of biomedical materials [J Mech Behav Biomed Mater] 2023 Oct; Vol. 146, pp. 106076. Date of Electronic Publication: 2023 Aug 14.
Publication Year :
2023

Abstract

Porous additively-manufactured structures could have a niche in orthopaedic implants, due to their potential to reduce stiffness (stress-shielding), improve bony ingrowth, and potential to house reservoirs of drug-eluting non-structural biomaterials. Computer aided design and finite element (FE) modelling plays an important role in the design of porous structured biomedical implants; however it is important to validate both their static and fatigue behaviours using experimental testing. This study compared the mechanical behaviors of titanium cylindrical gyroid structures of varying porosities using physical testing of additively manufactured prototypes and FE models. There was agreement in the measured and predicted relationships between porosity and apparent modulus of elasticity. As porosity increased (and wall thickness decreased), the structures failed at a lower number of cycles when loaded at the same percentage of their yield strengths. Calibration of the fatigue strength coefficient from a previously published value of 1586.5 MPa-1225 MPa greatly improved the fatigue life prediction accuracy for all the gyroid structures. Nevertheless, differences of up to 54% in the predicted versus experimental fatigue lives remained, which could be attributed to difficulties with how the precise time and location of failure is defined in the simulations, and/or minor differences in nominal and actual porosities. Although further calibration and validation should be explored, this study demonstrates that static and fatigue FE-modelling techniques could be used to aid in the design of porous prosthetics.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.The authors declare the following financial interests/personal relationships which may be considered as potential competing interests:Sydney Hitchon reports financial support was provided by Government of Canada.<br /> (Copyright © 2023 Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1878-0180
Volume :
146
Database :
MEDLINE
Journal :
Journal of the mechanical behavior of biomedical materials
Publication Type :
Academic Journal
Accession number :
37598509
Full Text :
https://doi.org/10.1016/j.jmbbm.2023.106076