Back to Search Start Over

Radiographic Assessment of Bone Quality Using 4 Radiographic Indexes: Canal Diaphysis Ratio Is Superior.

Authors :
Faundez J
Carmona M
Klaber I
Zamora T
Botello E
Schweitzer D
Source :
The Journal of arthroplasty [J Arthroplasty] 2024 Feb; Vol. 39 (2), pp. 427-432. Date of Electronic Publication: 2023 Aug 18.
Publication Year :
2024

Abstract

Background: Osteoporosis increases the risk of periprosthetic fracture and loosening in hip arthroplasty. Many methods have been proposed to assess bone quality in X-rays, including both qualitative such as the Dorr classification and quantitative such as the Calcar-Canal Ratio (CCR) and Cortical-Thickness index/Canal-Bone ratio (CTI/CBR). The Canal-Diaphysis ratio (CDR) has been described as a predictor for hip fragility fractures; however, its relationship with bone mineral density (BMD) has not been described. The purpose of this study was to evaluate the correlation of the Dorr classification, CCR, CTI/CBR, and CDR with BMD of the proximal femur in patients without hip fracture.<br />Methods: Forty-seven patients over 45 years of age who had less than 6 months between radiographs and dual-energy X-ray absorptiometry were evaluated. Measurements of CCR, CBR, CDR, and Dorr classification were performed in all radiographs by 2 independent observers.<br />Results: The CDR had a high correlation (r = 0.74, P=<0.01) with BMD, whereas the CTI/CBR had a moderate correlation (r = 0.49, P=<0.01), and the CCR had no correlation with BMD (r = 0.06, P = .96). When evaluating the receiver operating characteristic curve, CDR showed the best performance (area under curve [AUC] = 0.75) followed by CBR (AUC = 0.73) and CCR (AUC = 0.61). The optimal cutoff value for the CDR was 0.49, with 100% sensitivity and 58% specificity. The inter- and intra-observer variability was good for all methods. No differences were found between Dorr classification of patients who had or did not have osteoporosis.<br />Conclusion: Of all the analyzed methods, the CDR was found to have the best correlation with BMD. This study proposes the use of CDR as a tool for assessing bone quality when deciding the implant fixation method in hip arthroplasty.<br /> (Copyright © 2023 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1532-8406
Volume :
39
Issue :
2
Database :
MEDLINE
Journal :
The Journal of arthroplasty
Publication Type :
Academic Journal
Accession number :
37597819
Full Text :
https://doi.org/10.1016/j.arth.2023.08.037