Back to Search Start Over

Amyloid Transthyretin Cardiomyopathy in Elderly Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation.

Authors :
Dobner S
Pilgrim T
Hagemeyer D
Heg D
Lanz J
Reusser N
Gräni C
Afshar-Oromieh A
Rominger A
Langhammer B
Reineke D
Windecker S
Stortecky S
Source :
Journal of the American Heart Association [J Am Heart Assoc] 2023 Aug 15; Vol. 12 (16), pp. e030271. Date of Electronic Publication: 2023 Aug 10.
Publication Year :
2023

Abstract

Background The prevalence of calcific aortic stenosis and amyloid transthyretin cardiomyopathy (ATTR-CM) increase with age, and they often coexist. The objective was to determine the prevalence of ATTR-CM in patients with severe aortic stenosis and evaluate differences in presentations and outcomes of patients with concomitant ATTR-CM undergoing transcatheter aortic valve implantation. Methods and Results Prospective screening for ATTR-CM with Technetium <superscript>99</superscript> -3,3-diphosphono-1,2-propanodicarboxylic acid bone scintigraphy was performed in 315 patients referred with severe aortic stenosis between August 2019 and August 2021. Myocardial Technetium <superscript>99</superscript> -3,3-diphosphono-1,2-propanodicarboxylic acid tracer uptake was detected in 34 patients (10.8%), leading to a diagnosis of ATTR-CM in 30 patients (Perugini ≥2: 9.5%). Age (85.7±4.9 versus 82.8±4.5; P =0.001), male sex (82.4% versus 57.7%; P =0.005), and prior carpal tunnel surgery (17.6% versus 4.3%; P =0.007) were associated with coexisting ATTR-CM, as were ECG (discordant QRS voltage to left ventricular wall thickness [42% versus 12%; P <0.001]), echocardiographic (left ventricular ejection fraction 48.8±12.8 versus 58.4±10.8; P <0.001; left ventricular mass index, 144.4±45.8 versus 117.2±34.4g/m <superscript>2</superscript> ; P <0.001), and hemodynamic parameters (mean aortic valve gradient, 23.4±12.6 versus 35.5±16.6; P <0.001; mean pulmonary artery pressure, 29.5±9.7 versus 25.8±9.5; P =0.037). Periprocedural (cardiovascular death: hazard ratio [HR], 0.71 [95% CI, 0.04-12.53]; stroke: HR, 0.46 [95% CI, 0.03-7.77]; pacemaker implantation: HR, 1.54 [95% CI, 0.69-3.43]) and 1-year clinical outcomes (cardiovascular death: HR, 1.04 [95% CI, 0.37-2.96]; stroke: HR, 0.34 [95% CI, 0.02-5.63]; pacemaker implantation: HR, 1.50 [95% CI, 0.67-3.34]) were similar between groups. Conclusions Coexisting ATTR-CM was observed in every 10th elderly patient with severe aortic stenosis referred for therapy. While patients with coexisting pathologies differ in clinical presentation and echocardiographic and hemodynamic parameters, peri-interventional risk and early clinical outcomes were comparable up to 1 year after transcatheter aortic valve implantation. REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifier: NCT04061213.

Details

Language :
English
ISSN :
2047-9980
Volume :
12
Issue :
16
Database :
MEDLINE
Journal :
Journal of the American Heart Association
Publication Type :
Academic Journal
Accession number :
37581394
Full Text :
https://doi.org/10.1161/JAHA.123.030271