Automated and semi-automated 3D echocardiographic software for aortic annulus sizing in transcatheter aortic valve implantation helps bridge the gap between expert and novice operators.
- Source :
-
The international journal of cardiovascular imaging [Int J Cardiovasc Imaging] 2023 Sep; Vol. 39 (9), pp. 1707-1717. Date of Electronic Publication: 2023 Aug 12. - Publication Year :
- 2023
-
Abstract
- 3D-transesophageal echocardiography (3D-TEE) is an alternative to multidetector row computed tomography (MDCT) for aortic annulus (AoA) sizing in preparation for Transcatheter aortic valve implantation (TAVI). We aim to evaluate how the fully automated (auto) and semi-automated (SA) TEE methods perform compared to conventional manual TEE method and the gold standard MDCT for annulus sizing both in expert and novice operators. In this prospective cohort study, eighty-nine patients with severe aortic stenosis underwent multimodality imaging with 3D-TEE and MDCT. Annular measurements were collected by expert echocardiographers using 3D auto, SA and manual methods and compared to MDCT. A novice in the field of echocardiography retrospectively measured the AoA for all patients using the same methods. TEE measurements, independently of the method used, had good to very good agreement to MDCT. They significantly underestimated aortic annular area and circumference vs. MDCT with the auto method underestimating it the most and the manual method the least (6.5% and 1.3% respectively for area and circumference). For experts, the manual TEE method offered the least systematic bias while the SA method had narrower limits of agreement (LOA). For the novice operator, SA method provided the least bias and narrower LOA vs. MDCT. There is good agreement between novice and experts for all 3 TEE methods but better agreement with auto and SA methods as opposed to manual one. Our study supports the use of 3D-TEE as a complementary method to MDCT for aortic annular sizing. The newer auto and SA software, that requires minimal operator intervention, is an easy to use, reliable and reproducible tool for aortic annulus sizing for experienced operators, and especially less experienced ones.<br /> (© 2023. The Author(s).)
- Subjects :
- Humans
Aortic Valve diagnostic imaging
Aortic Valve surgery
Retrospective Studies
Prospective Studies
Predictive Value of Tests
Software
Echocardiography, Transesophageal methods
Multidetector Computed Tomography methods
Transcatheter Aortic Valve Replacement adverse effects
Aortic Valve Stenosis diagnostic imaging
Aortic Valve Stenosis surgery
Echocardiography, Three-Dimensional methods
Heart Valve Prosthesis Implantation
Subjects
Details
- Language :
- English
- ISSN :
- 1875-8312
- Volume :
- 39
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- The international journal of cardiovascular imaging
- Publication Type :
- Academic Journal
- Accession number :
- 37572176
- Full Text :
- https://doi.org/10.1007/s10554-023-02885-z