Back to Search Start Over

Loss or Dilution-A New Diagnostic Method to Assess the Impact of Dilution on Standard Laboratory Parameters.

Authors :
Innerhofer N
Rajsic S
Ronzani M
Breitkopf R
Gollmann Tepeköylü C
Velik-Salchner C
Schlosser L
Fries D
Streif W
Schirmer M
Martini J
Source :
Diagnostics (Basel, Switzerland) [Diagnostics (Basel)] 2023 Aug 04; Vol. 13 (15). Date of Electronic Publication: 2023 Aug 04.
Publication Year :
2023

Abstract

Intraoperative fluid therapy is regularly used in patients undergoing cardiac surgery procedures with cardiopulmonary bypass (CPB). Although fluid administration has several advantages, it unavoidably leads to hemodilution. The hemodilution may further influence the interpretation of concentration-based laboratory parameters like hemoglobin (Hgb), platelet count (PLT) or prothrombin time (PT). These all parameters are commonly used to guide blood product substitution. To assess the impact of dilution on these values, we performed a prospective observational study in 174 patients undergoing elective cardiac surgery. We calculated the total blood volume according to Nadler's formula, and fluid therapy was correlated with a newly developed dilution coefficient formula at the end of CPB. Intravenously applied fluids were measured from the beginning of the anesthesia (baseline, T <subscript>0</subscript> ) and 15 min after the end of protamine infusion (end of CPB, T <subscript>1</subscript> ). The amount of the administered volume (crystalloids or colloids) was calculated according to the percentage of the intravascular fluid effect, and intraoperative diuresis was further subtracted. The median blood volume increased by 148% in all patients at T <subscript>1</subscript> compared to the calculated total blood volume at T <subscript>0</subscript> . This led to a dilution-dependent decrease of 38% in all three parameters (Hgb 24%, corrCoeff = 0.53; PLT 41%, corrCoeff = 0.68; PT 44%, corrCoeff = 0.54). The dilution-correlated decrease was significant for all parameters ( p < 0.001), and the effect was independent from the duration of CPB. We conclude that the presented calculation-based approach could provide important information regarding actual laboratory parameters and may help in the guidance of the blood product substitution and potential transfusion thresholds. Further research on the impact of dilution and related decision-making for blood product substitution, including its impact on morbidity and mortality, is warranted.

Details

Language :
English
ISSN :
2075-4418
Volume :
13
Issue :
15
Database :
MEDLINE
Journal :
Diagnostics (Basel, Switzerland)
Publication Type :
Academic Journal
Accession number :
37568959
Full Text :
https://doi.org/10.3390/diagnostics13152596