Post-Shock Asystole in Patients Dying Out of Hospital While Wearing a Cardioverter Defibrillator.
- Source :
-
JACC. Clinical electrophysiology [JACC Clin Electrophysiol] 2023 Aug; Vol. 9 (8 Pt 1), pp. 1333-1339. Date of Electronic Publication: 2023 Feb 22. - Publication Year :
- 2023
-
Abstract
- Background: The wearable cardioverter-defibrillator (WCD) prevents sudden cardiac death due to ventricular tachycardia (VT) or ventricular fibrillation (VF) but does not pace for post-shock asystole (PS-A) or bradycardia (PS-B;<50 beats/ min).<br />Objectives: The purpose of this study was to assess PS-A and PS-B in patients dying out of hospital (OOH) while wearing a WCD.<br />Methods: The database of the U.S. Food and Drug Administration Manufacturers and User Facility Device Experience (MAUDE) was queried for manufacturers' reports of OOH deaths while patients were wearing a WCD. Excluded were patients who did not receive a shock or were initially shocked for asystole or during resuscitation.<br />Results: From January 2017 to March 2022, 313 patients received an initial WCD shock for VF (n = 150), VT (n = 90), and non-VF/VT rhythms (n = 73). PS-A occurred in 204 patients (65.2%), and PS-B occurred in 111 (35.5%); 85 (41.7%) PS-A patients also had PS-B. Most PS-A patients (n = 185; 90.7%) had an initial shocked rhythm of VF or VT, but 19 patients (9.3%) were initially inappropriately shocked for atrial fibrillation/supraventricular tachycardia (n = 7) and idioventricular (n = 8) or sinus (n = 4) rhythm. PS-A occurred after the first WCD shock in 118 (63.8%) and after the first, second, or third shocks in 159 patients (85.9%). Seven patients had post-shock heart block. Eight patients had permanent pacemakers; 1 became nonfunctional after 1 shock, and 7 showed noncapture and/or asystole after 1 to 4 shocks.<br />Conclusions: Post-shock asystole appears to be common in patients who die OOH after being shocked by a WCD for VF or VT. PS-A also occurs after inappropriate WCD shocks for non-VF/VT rhythms. Implanted pacemakers may not prevent PS-A after a WCD shock. WCD backup pacing should be explored.<br />Competing Interests: Funding Support and Author Disclosures The Minneapolis Heart Institute Foundation funded this study. The authors have reported that they have no relationships relevant to the contents of this paper to disclose.<br /> (Copyright © 2023 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 2405-5018
- Volume :
- 9
- Issue :
- 8 Pt 1
- Database :
- MEDLINE
- Journal :
- JACC. Clinical electrophysiology
- Publication Type :
- Academic Journal
- Accession number :
- 37558289
- Full Text :
- https://doi.org/10.1016/j.jacep.2022.12.016