Back to Search Start Over

An artificial intelligence algorithm for pulmonary embolism detection on polychromatic computed tomography: performance on virtual monochromatic images.

Authors :
Langius-Wiffen E
Nijholt IM
van Dijk RA
de Boer E
Nijboer-Oosterveld J
Veldhuis WB
de Jong PA
Boomsma MF
Source :
European radiology [Eur Radiol] 2024 Jan; Vol. 34 (1), pp. 384-390. Date of Electronic Publication: 2023 Aug 05.
Publication Year :
2024

Abstract

Objectives: Virtual monochromatic images (VMI) are increasingly used in clinical practice as they improve contrast-to-noise ratio. However, due to their different appearances, the performance of artificial intelligence (AI) trained on conventional CT images may worsen. The goal of this study was to assess the performance of an established AI algorithm trained on conventional polychromatic computed tomography (CT) images (CPI) to detect pulmonary embolism (PE) on VMI.<br />Methods: Paired 60 kiloelectron volt (keV) VMI and CPI of 114 consecutive patients suspected of PE, obtained with a detector-based spectral CT scanner, were retrospectively analyzed by an established AI algorithm. The CT pulmonary angiography (CTPA) were classified as positive or negative for PE on a per-patient level. The reference standard was established using a comprehensive method that combined the evaluation of the attending radiologist and three experienced cardiothoracic radiologists aided by two different detection tools. Sensitivity, specificity, positive and negative predictive values and likelihood ratios of the algorithm on VMI and CPI were compared.<br />Results: The prevalence of PE according to the reference standard was 35.1% (40 patients). None of the diagnostic accuracy measures of the algorithm showed a significant difference between CPI and VMI. Sensitivity was 77.5% (95% confidence interval (CI) 64.6-90.4%) and 85.0% (73.9-96.1%) (p = 0.08) on CPI and VMI respectively and specificity 96.0% (91.4-100.0%) and 94.6% (89.4-99.7%) (p = 0.32).<br />Conclusions: Diagnostic performance of the AI algorithm that was trained on CPI did not drop on VMI, which is reassuring for its use in clinical practice.<br />Clinical Relevance Statement: A commercially available AI algorithm, trained on conventional polychromatic CTPA, could be safely used on virtual monochromatic images. This supports the sustainability of AI-aided detection of PE on CT despite ongoing technological advances in medical imaging, although monitoring in daily practice will remain important.<br />Key Points: • Diagnostic accuracy of an AI algorithm trained on conventional polychromatic images to detect PE did not drop on virtual monochromatic images. • Our results are reassuring as innovations in hardware and reconstruction in CT are continuing, whilst commercial AI algorithms that are trained on older generation data enter healthcare.<br /> (© 2023. The Author(s), under exclusive licence to European Society of Radiology.)

Details

Language :
English
ISSN :
1432-1084
Volume :
34
Issue :
1
Database :
MEDLINE
Journal :
European radiology
Publication Type :
Academic Journal
Accession number :
37542651
Full Text :
https://doi.org/10.1007/s00330-023-10048-w