Back to Search
Start Over
Handheld chromatic pupillometry can reliably detect functional glaucomatous damage in eyes with high myopia.
- Source :
-
The British journal of ophthalmology [Br J Ophthalmol] 2024 May 21; Vol. 108 (6), pp. 818-825. Date of Electronic Publication: 2024 May 21. - Publication Year :
- 2024
-
Abstract
- Background/aims: To assess pupillary light responses (PLRs) in eyes with high myopia (HM) and evaluate the ability of handheld chromatic pupillometry (HCP) to identify glaucomatous functional loss in eyes with HM.<br />Methods: This prospective, cross-sectional study included 28 emmetropes (EM), 24 high myopes without glaucoma (HM) and 17 high myopes with confirmed glaucoma (HMG), recruited at the Singapore National Eye Center. Monocular PLRs were evaluated using a custom-built handheld pupillometer that recorded changes in horizontal pupil radius in response to 9 s of exponentially increasing blue (469.1 nm) and red (640.1 nm) lights. Fifteen pupillometric features were compared between groups. A logistic regression model (LRM) was used to distinguish HMG eyes from non-glaucomatous eyes (EM and HM).<br />Results: All pupillometric features were similar between EM and HM groups. Phasic constriction to blue (p<0.001) and red (p=0.006) lights, and maximum constriction to blue light (p<0.001) were reduced in HMG compared with EM and HM. Pupillometric features of melanopsin function (postillumination pupillary response, PIPR area under the curve (AUC) 0-12 s (p<0.001) and PIPR 6 s (p=0.01) to blue light) were reduced in HMG. Using only three pupillometric features, the LRM could classify glaucomatous from non-glaucomatous eyes with an AUC of 0.89 (95% CI 0.77 to 1.00), sensitivity 94.1% (95% CI 82.4% to 100.0%) and specificity 78.8% (95% CI 67.3% to 90.4%).<br />Conclusion: PLRs to ramping-up light stimuli are unaltered in highly myopic eyes without other diagnosed ocular conditions. Conversely, HCP can distinguish glaucomatous functional loss in eyes with HM and can be a useful tool to detect/confirm the presence of glaucoma in patients with HM.<br />Competing Interests: Competing interests: RPN, DM and TA have a patent application based on the handheld pupillometer used in this study (PCT/SG2018/050204): Handheld ophthalmic and neurological screening device. The rest of the authors have no conflicts of interest to disclose.<br /> (© Author(s) (or their employer(s)) 2024. No commercial re-use. See rights and permissions. Published by BMJ.)
- Subjects :
- Humans
Cross-Sectional Studies
Male
Prospective Studies
Female
Adult
Middle Aged
Visual Fields physiology
Myopia, Degenerative physiopathology
Myopia, Degenerative diagnosis
ROC Curve
Glaucoma physiopathology
Glaucoma diagnosis
Reproducibility of Results
Diagnostic Techniques, Ophthalmological instrumentation
Young Adult
Light
Intraocular Pressure physiology
Pupil physiology
Reflex, Pupillary physiology
Subjects
Details
- Language :
- English
- ISSN :
- 1468-2079
- Volume :
- 108
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- The British journal of ophthalmology
- Publication Type :
- Academic Journal
- Accession number :
- 37524446
- Full Text :
- https://doi.org/10.1136/bjo-2023-323878