Pulmonary vein isolation durability and lesion regression in patients with recurrent arrhythmia after pulsed-field ablation.

Authors :
Kueffer T
Stefanova A
Madaffari A
Seiler J
Thalmann G
Kozhuharov N
Maurhofer J
Galuszka O
Haeberlin A
Noti F
Servatius H
Tanner H
Roten L
Reichlin T
Source :
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing [J Interv Card Electrophysiol] 2024 Apr; Vol. 67 (3), pp. 503-511. Date of Electronic Publication: 2023 Jul 31.
Publication Year :
2024

Abstract

Background: A novel multipolar pulsed-field ablation (PFA) catheter has recently been introduced for pulmonary vein isolation (PVI). Pre-market data showed high rates for PVI-durability during mandatory remapping studies.<br />Objective: To present post-market data in patients with recurrent arrhythmias.<br />Methods: Consecutive patients undergoing a redo procedure after an index PFA PVI using a bipolar-biphasic PFA system were included. 3-D electro-anatomical maps (3D-EAM) on redo procedure were compared to the 3D-EAM acquired after ablation during the index procedure. PVI durability was assessed on a per-vein and per-patient level and the sites of reconnections were identified. Furthermore, lesion extent around veins with durable isolation was compared to study lesion regression.<br />Results: Of 341 patients treated with a PFA PVI, 29 (8.5%) underwent a left atrial redo ablation due to arrhythmia recurrence. At the end of the index procedure, 110/112 veins (98%, four common ostia) were isolated. On redo procedures performed a median of 6 months after the first ablation, 3D-EAM identified 69/110 (63%) PVs with durable isolation. In 6 (21%) patients, all PVs were durably isolated. Reconnections were more often found on the right-sided veins and on the anterior aspects of the upper veins. Only minor lesion regression was observed between the index and redo procedure (a median of 3 mm (0 - 9.5) on the posterior wall).<br />Conclusion: In patients with arrhythmia recurrence after PFA PVI using a first-generation PFA device, durable isolation was observed in 63% of the veins and 21% of the patients showed durable isolation of all previously isolated veins.<br /> (© 2024. The Author(s).)

Details

Language :
English
ISSN :
1572-8595
Volume :
67
Issue :
3
Database :
MEDLINE
Journal :
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
Publication Type :
Academic Journal
Accession number :
37523023
Full Text :
https://doi.org/10.1007/s10840-023-01608-7