Design and rationale of the MODULAR ATP global clinical trial: A novel intercommunicative leadless pacing system and the subcutaneous implantable cardioverter-defibrillator.

Authors :
Lloyd MS
Brisben AJ
Reddy VY
Blomström-Lundqvist C
Boersma LVA
Bongiorni MG
Burke MC
Cantillon DJ
Doshi R
Friedman PA
Gras D
Kutalek SP
Neuzil P
Roberts PR
Wright DJ
Appl U
West J
Carter N
Stein KM
Mont L
Knops RE
Source :
Heart rhythm O2 [Heart Rhythm O2] 2023 Jun 02; Vol. 4 (7), pp. 448-456. Date of Electronic Publication: 2023 Jun 02 (Print Publication: 2023).
Publication Year :
2023

Abstract

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support.<br />Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented.<br />Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years.<br />Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described.<br />Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.<br /> (© 2023 Heart Rhythm Society. Published by Elsevier Inc.)

Details

Language :
English
ISSN :
2666-5018
Volume :
4
Issue :
7
Database :
MEDLINE
Journal :
Heart rhythm O2
Publication Type :
Academic Journal
Accession number :
37520021
Full Text :
https://doi.org/10.1016/j.hroo.2023.05.004