Back to Search Start Over

The Use of Impella 5.5 for Donor-Heart Hemodynamic Support in Heart Transplantation.

Authors :
Kawabori M
David B
Nordan T
Chen FY
Couper GS
Source :
ASAIO journal (American Society for Artificial Internal Organs : 1992) [ASAIO J] 2023 Dec 01; Vol. 69 (12), pp. e520-e522. Date of Electronic Publication: 2023 Jul 27.
Publication Year :
2023

Abstract

Primary graft dysfunction is a feared complication and cause of mortality post-heart transplant. Primary graft dysfunction may require mechanical circulatory support, such as venoarterial extracorporeal membrane oxygenation, which carries its own risk for complications. We developed a new mechanical circulatory support method for patients who underwent heart transplant bridged with Impella 5.5, which was then placed into the donor heart. Among 12 heart transplants, four required Impella 5.5 support. The average age was 55.8 years. The mean duration for postoperative mechanical circulatory support was 3.8 days, ranging from 2 to 5 days. No patients developed severe right ventricular dysfunction. In our limited study, complications and mortality associated with the replanted Impella 5.5 were both 0%.<br />Competing Interests: Disclosure: The authors have no conflicts of interest to report.<br /> (Copyright © ASAIO 2023.)

Details

Language :
English
ISSN :
1538-943X
Volume :
69
Issue :
12
Database :
MEDLINE
Journal :
ASAIO journal (American Society for Artificial Internal Organs : 1992)
Publication Type :
Academic Journal
Accession number :
37499690
Full Text :
https://doi.org/10.1097/MAT.0000000000002022