Back to Search Start Over

Three-dimensional finite element study of mandibular first molar distalization with clear aligner.

Authors :
Kang F
Yu L
Zhang Q
Li X
Hu Z
Zhu X
Source :
Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology [Hua Xi Kou Qiang Yi Xue Za Zhi] 2023 Aug 01; Vol. 41 (4), pp. 405-413.
Publication Year :
2023

Abstract

Objectives: This study aimed to construct the finite element model of the mandibular first molar with the invisible appliance and explore the dentition movement characteristics of the mandibular first molar when using micro-implant anchorage and different initial positions of the first molar.<br />Methods: Models of the mandible, tooth, periodontal membrane, and invisible appliance were constructed using cone beam computed tomography (CBCT) data. The two groups were divided into the non-anchorage group and the micro-implant group (between the roots of the first molar and the second molar) based on whether the elastic traction of the micro-implant was assisted or not. The two groups were divided into the following conditions based on the starting position of the first molar: Working condition 1: the distance between the first molar and the second premolar was 0 mm; working condition 2: the distance between the first molar and the second premolar was 1 mm; working condition 3: the distance between the first molar and the second premolar was 2 mm; working condition 4: the distance between the first molar and the second premolar was 3 mm. The data characte-ristics of total displacement and displacement in each direction of dentition were analyzed.<br />Results: In the non-ancho-rage group, all the other teeth showed reverse movement except for the first molar which was moved distally. Meanwhile, in the micro-implant group, except for a small amount of mesial movement of the second molar in wor-king condition 1, the whole dentition in other working conditions presented distal movement and anterior teeth showed lingual movement, among which the distal displacement of the first molar in working condition 4 was the largest. With the change of the initial position of the first molar to the distal, the movement of the first molar to the distal, the premolar to the mesial, and the anterior to the lip increased, while the movement of the second molar to the mesial decreased.<br />Conclusions: The micro-implant can effectively protect the anterior anchorage, increase the expression rate of molar distancing, and avoid the round-trip movement of the second molar. The initial position of the first molar movement is related to the amount of distancing and the remaining tooth movement.

Details

Language :
English; Chinese
ISSN :
2618-0456
Volume :
41
Issue :
4
Database :
MEDLINE
Journal :
Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology
Publication Type :
Academic Journal
Accession number :
37474472
Full Text :
https://doi.org/10.7518/hxkq.2023.2023021