Back to Search
Start Over
Self-expanding TAVI using the cusp overlap technique versus the traditional technique: electrocardiogram changes and 1-year cardiovascular outcomes.
- Source :
-
Revista espanola de cardiologia (English ed.) [Rev Esp Cardiol (Engl Ed)] 2024 Jan; Vol. 77 (1), pp. 29-38. Date of Electronic Publication: 2023 Jul 10. - Publication Year :
- 2024
-
Abstract
- Introduction and Objectives: Transcatheter aortic valve implantation (TAVI) using the cusp overlap technique (COT) has shown a lower pacemaker implantation rate at 30 days. The objective of this study was to compare electrocardiogram changes and clinical outcomes between COT and the traditional technique (TT) at 1 year of follow-up.<br />Methods: Observational, retrospective, nonrandomized study of consecutive patients undergoing TAVI between January 2015 and January 2021. Patients were matched using a propensity score and the TT was compared with COT. The primary endpoints were electrocardiogram changes and a combined endpoint including pacemaker implantation, hospitalization, or cardiovascular death at 1 year.<br />Results: We included 254 patients. After propensity score matching, 184 patients (92 per group) remained. There were no statistically significant differences in baseline characteristics. At 1 year, COT patients showed a significant reduction in new onset left bundle branch block (49% vs 27%, P=.002) and less P wave (13.1±21.0 msec vs 5.47±12.5 msec; P=.003) and QRS prolongation (29.77±27.0 msec vs 16.38±25.4 msec, P <.001). COT was associated with a significant reduction in the occurrence of the primary endpoint (SHR, 0.39 [IC95%, 0.21-0.76]; P=.005).<br />Conclusions: At 1 year of follow-up, COT reduced the incidence of new onset left bundle branch block and diminished QRS and P wave widening compared with the TT. COT was also associated with a statistically significant reduction in the occurrence of the combined primary cardiovascular endpoint.<br /> (Copyright © 2023 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.)
- Subjects :
- Humans
Bundle-Branch Block complications
Retrospective Studies
Cardiac Pacing, Artificial adverse effects
Arrhythmias, Cardiac therapy
Electrocardiography
Treatment Outcome
Aortic Valve diagnostic imaging
Aortic Valve surgery
Transcatheter Aortic Valve Replacement adverse effects
Aortic Valve Stenosis diagnosis
Aortic Valve Stenosis surgery
Aortic Valve Stenosis complications
Heart Valve Prosthesis adverse effects
Pacemaker, Artificial adverse effects
Subjects
Details
- Language :
- English; Spanish; Castilian
- ISSN :
- 1885-5857
- Volume :
- 77
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Revista espanola de cardiologia (English ed.)
- Publication Type :
- Academic Journal
- Accession number :
- 37437882
- Full Text :
- https://doi.org/10.1016/j.rec.2023.04.008