Accuracy of non-invasive sensors measuring core body temperature in cardiac surgery ICU patients - results from a monocentric prospective observational study.
- Source :
-
Journal of clinical monitoring and computing [J Clin Monit Comput] 2023 Dec; Vol. 37 (6), pp. 1619-1626. Date of Electronic Publication: 2023 Jul 12. - Publication Year :
- 2023
-
Abstract
- Purpose: Temperature monitoring in the perioperative setting often represents a compromise between accuracy, invasiveness of probe placement, and patient comfort. Transcutaneous sensors using the Zero-Heat-Flux (ZHF) and Double-Sensor (DS) technology have been developed and evaluated in a variety of clinical settings. The present study is the first to compare the performance of both sensors simultaneously with temperature measured by a Swan-Ganz catheter (PAC) in patients admitted to the intensive care unit (ICU) after cardiac surgery.<br />Methods: In this monocentric prospective observational study patients were postoperatively transferred to the ICU and both sensors were placed on the patients' foreheads. Core body temperature measured by intraoperatively placed PAC served as gold standard. Measurements were recorded at 5-minute intervals and up to 40 data sets per patient were recorded. Bland and Altman's method for repeated measurements was used to analyse agreement. Subgroup analyses for gender, body-mass-index, core temperature, airway status and different time intervals were performed. Lin's concordance correlation coefficient (LCCC) was calculated, as well as sensitivity and specificity for detecting hyperthermia (≥ 38 °C) and hypothermia (< 36 °C).<br />Results: Over a period of six month, we collected 1600 sets of DS, ZHF, and PAC measurements, from a total of 40 patients. Bland-Altman analysis revealed a mean bias of -0.82 ± 1.27 °C (average ± 95% Limits-of-Agreement (LoA)) and - 0.54 ± 1.14 °C for DS and ZHF, respectively. The LCCC was 0.5 (DS) and 0.63 (ZHF). Mean bias was significantly higher in hyperthermic and hypothermic patients. Sensitivity and specificity were 0.12 / 0.99 (DS) and 0.35 / 1.0 (ZHF) for hyperthermia and 0.95 / 0.72 (DS) and 1.0 / 0.85 (ZHF) for hypothermia.<br />Conclusion: Core temperature was generally underestimated by the non-invasive approaches. In our study, ZHF outperformed DS. In terms of agreement, results for both sensors were outside the range that is considered clinically acceptable. Nevertheless, both sensors might be adequate to detect postoperative hypothermia reliably when more invasive methods are not available or appropriate.<br />Trial Registration: German Register of Clinical Trials (DRKS-ID: DRKS00027003), retrospectively registered 10/28/2021.<br /> (© 2023. The Author(s).)
Details
- Language :
- English
- ISSN :
- 1573-2614
- Volume :
- 37
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Journal of clinical monitoring and computing
- Publication Type :
- Academic Journal
- Accession number :
- 37436599
- Full Text :
- https://doi.org/10.1007/s10877-023-01049-7