Back to Search Start Over

Effect of 3-Dimensional Imaging Device on Polyp and Adenoma Detection During Colonoscopy: A Randomized Controlled Trial.

Authors :
Sun X
Zhang Q
Wu S
Xu C
Zhang Y
Hao X
Meng Y
Jiao Y
Li H
Zhu S
Zhou Y
Liu K
Xu H
Zhu S
Zhang S
Source :
The American journal of gastroenterology [Am J Gastroenterol] 2023 Oct 01; Vol. 118 (10), pp. 1812-1820. Date of Electronic Publication: 2023 Jul 07.
Publication Year :
2023

Abstract

Introduction: To evaluate the effect of 3-dimensional (3D) imaging device on polyp and adenoma detection during colonoscopy.<br />Methods: In a single-blind, randomized controlled trial, participants aged 18-70 years who underwent diagnostic or screening colonoscopy were consecutively enrolled between August 2019 and May 2022. Each participant was randomized in a 1:1 ratio to undergo either 2-dimensional (2D-3D) colonoscopy or 3D-2D colonoscopy through computer-generated random numbers. Primary outcome included polyp detection rate (PDR) and adenoma detection rate (ADR), defined as the proportion of individuals with at least 1 polyp or adenoma detected during colonoscopy. The primary analysis was intention-to-treat.<br />Results: Of 1,196 participants recruited, 571 in 2D-3D group and 583 in 3D-2D group were finally included after excluding those who met the exclusion criteria. The PDR between 2D and 3D groups was separately 39.6% and 40.5% during phase 1 (odds ratio [OR] = 0.96, 95% confidence interval [CI]: 0.76-1.22, P = 0.801), whereas PDR was significantly higher in 3D group (27.7%) than that of 2D group (19.9%) during phase 2, with a 1.54-fold increase (1.17-2.02, P = 0.002). Similarly, the ADR during phase 1 between 2D (24.7%) and 3D (23.8%) groups was not significant (OR = 1.05, 0.80-1.37, P = 0.788), while ADR was significantly higher in 3D group (13.8%) than that of 2D group (9.9%) during phase 2, with a 1.45-fold increase (1.01-2.08, P = 0.041). Further subgroup analysis confirmed significantly higher PDR and ADR of 3D group during phase 2, particularly in midlevel and junior endoscopists.<br />Discussion: The 3D imaging device could improve overall PDR and ADR during colonoscopy, particularly in midlevel and junior endoscopists. Trial number: ChiCTR1900025000.<br /> (Copyright © 2023 by The American College of Gastroenterology.)

Details

Language :
English
ISSN :
1572-0241
Volume :
118
Issue :
10
Database :
MEDLINE
Journal :
The American journal of gastroenterology
Publication Type :
Academic Journal
Accession number :
37410933
Full Text :
https://doi.org/10.14309/ajg.0000000000002396