Back to Search Start Over

Rethinking of TEER measurement reporting for epithelial cells grown on permeable inserts.

Authors :
Karakocak BB
Keshavan S
Gunasingam G
Angeloni S
Auderset A
Petri-Fink A
Rothen-Rutishauser B
Source :
European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences [Eur J Pharm Sci] 2023 Sep 01; Vol. 188, pp. 106511. Date of Electronic Publication: 2023 Jun 28.
Publication Year :
2023

Abstract

Transepithelial electrical resistance (TEER) measures electrical resistance across epithelial tissue barriers involving confluent layer(s) of cells. TEER values act as a prerequisite for determining the barrier integrity of cells, which play a key role in evaluating the transport of drugs, materials or chemicals of interest across an epithelial barrier. The measurements can be performed non-invasively by measuring ohmic resistance across a defined area. Thus, the TEER values are reported in Ω·cm <superscript>2</superscript> . In vitro epithelial models are typically assembled on semi-permeable inserts providing two-chamber compartments, and the majority of the studies use inserts with polyethylene terephthalate (PET) membranes. Recently, new inserts with different membrane types and properties have been introduced. However, the TEER values presented so far did not allow a direct comparison. This study presents the characterization of selected epithelial tissues, i.e., lung, retina, and intestine, grown on an ultra-thin ceramic microporous permeable insert (SiMPLI) and PET membranes with different properties, i.e., thickness, material, and pore numbers. We verified the epithelial cell growth on both inserts via phase-contrast and confocal laser scanning microscope imaging. Barrier characteristics were assessed by TEER measurements and also by evaluating the permeability of fluorescein isothiocyanate through cell layers. The findings indicated that background TEER value calculations and the available surface area for cell growth must be thoroughly assessed when new inserts are introduced, as the values cannot be directly compared without re-calculations. Finally, we proposed electrical circuit models highlighting the contributors to TEER recordings on PET and SiMPLI insert membranes. This study paves the way for making the ohmic-based evaluation of epithelial tissues' permeability independent of the material and geometry of the insert membrane used for cell growth.<br />Competing Interests: Declaration of Competing Interest Silvia Angeloni is the CEO - Founder of SiMPLInext SA. The authors declare that there are no conflicts of interest.<br /> (Copyright © 2023. Published by Elsevier B.V.)

Details

Language :
English
ISSN :
1879-0720
Volume :
188
Database :
MEDLINE
Journal :
European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences
Publication Type :
Academic Journal
Accession number :
37385303
Full Text :
https://doi.org/10.1016/j.ejps.2023.106511